T1 - A Method for Identification of the Equivalent Inductance and Resistance in the Plant Model of Current-Controlled Grid-Tied Converters
AU - Vidal, Ana
AU - Yepes, Alejandro G.
AU - Fernandez, Francisco Daniel Freijedo
AU - Lopez, Oscar
AU - Malvar, Jano
AU - Baneira, Fernando
AU - Doval-Gandoy, Jesus
PY - 2015/12
Y1 - 2015/12
N2 - Precise knowledge of the plant time constant L=R is essential to perform a thorough analysis and design of the current control loop in voltage source converters (VSCs). From the perspective of the current controller dynamics in the low frequency range, such plant time constant is also suitable for most cases in which an LCL filter is used. As the loop behavior can be significantly influenced by the VSC working conditions, the effects associated to converter losses should be included in the model, through an equivalent series resistance. In addition, the plant inductance may also present important uncertainties with respect to the value of the VSC L/LCL interface filter measured at rated conditions. Thus, in this work, a method is presented to estimate both parameters of the plant time constant, i.e., the equivalent inductance and resistance in the plant model of current-controlled VSCs. The proposed technique is based on the evaluation of the closed-loop transient responses of both axes of the synchronous reference frame when a proportional-integral current controller is implemented. The method gives a set of resistance and inductance values that should be employed for a rigorous design of the current controllers. Experimental results validate the approach.
AB - Precise knowledge of the plant time constant L=R is essential to perform a thorough analysis and design of the current control loop in voltage source converters (VSCs). From the perspective of the current controller dynamics in the low frequency range, such plant time constant is also suitable for most cases in which an LCL filter is used. As the loop behavior can be significantly influenced by the VSC working conditions, the effects associated to converter losses should be included in the model, through an equivalent series resistance. In addition, the plant inductance may also present important uncertainties with respect to the value of the VSC L/LCL interface filter measured at rated conditions. Thus, in this work, a method is presented to estimate both parameters of the plant time constant, i.e., the equivalent inductance and resistance in the plant model of current-controlled VSCs. The proposed technique is based on the evaluation of the closed-loop transient responses of both axes of the synchronous reference frame when a proportional-integral current controller is implemented. The method gives a set of resistance and inductance values that should be employed for a rigorous design of the current controllers. Experimental results validate the approach.
U2 - 10.1109/TPEL.2015.2395817
DO - 10.1109/TPEL.2015.2395817
M3 - Journal article
SN - 0885-8993
VL - 30
SP - 7245
EP - 7261
JO - I E E E Transactions on Power Electronics
JF - I E E E Transactions on Power Electronics
IS - 12
ER -