TY - JOUR
T1 - An Efficient and Robust Hybrid Damper for LCL- or LLCL-Based Grid-Tied Inverter With Strong Grid-Side Harmonic Voltage Effect Rejection
AU - Liu, Yuan
AU - Wu, Weimin
AU - He, Yuanbin
AU - Lin, Zhe
AU - Blaabjerg, Frede
AU - Chung, Henry Shu-Hung
PY - 2016
Y1 - 2016
N2 - A high-order (LCL or LLCL) power filter with a small grid-side inductor is becoming more preferred for a grid-tied inverter due to less total inductance and reduced costs. In a microgrid, the background harmonic voltage (BHV) may distort the injected currents of the grid-tied inverters. In order to resist the effect of the BHV, a feedforward voltage compensator and a proportional resonant regulator with harmonic compensation are often adopted. However, they still have their own limitations, particularly when there are higher order BHVs at the point of common coupling and when the equivalent grid impedance widely varies due to the different numbers of grid-tied inverters in parallel. Thus, an extra damper should be inserted to keep the system stable. In this paper, the control bandwidth limitation of a multiloop control active damping (AD) method is analyzed and illustrated by the capacitor-current-feedback AD. Based on this, a single-loop current control with a hybrid damper is proposed for a single-phase LCLor LLCL-filter-based grid-tied inverter. A step-by-step design of the controller method is also introduced in detail. Experiments on a 2-kW prototype fully demonstrate the strong robustness of the stability and the high harmonic rejection ability of the inverter using the proposed control method.
AB - A high-order (LCL or LLCL) power filter with a small grid-side inductor is becoming more preferred for a grid-tied inverter due to less total inductance and reduced costs. In a microgrid, the background harmonic voltage (BHV) may distort the injected currents of the grid-tied inverters. In order to resist the effect of the BHV, a feedforward voltage compensator and a proportional resonant regulator with harmonic compensation are often adopted. However, they still have their own limitations, particularly when there are higher order BHVs at the point of common coupling and when the equivalent grid impedance widely varies due to the different numbers of grid-tied inverters in parallel. Thus, an extra damper should be inserted to keep the system stable. In this paper, the control bandwidth limitation of a multiloop control active damping (AD) method is analyzed and illustrated by the capacitor-current-feedback AD. Based on this, a single-loop current control with a hybrid damper is proposed for a single-phase LCLor LLCL-filter-based grid-tied inverter. A step-by-step design of the controller method is also introduced in detail. Experiments on a 2-kW prototype fully demonstrate the strong robustness of the stability and the high harmonic rejection ability of the inverter using the proposed control method.
KW - Background harmonic voltage (BHV)
KW - Grid impedance variation
KW - Harmonic rejection ability
KW - LCL-filter
KW - LLCL-filter
KW - Notch filter
KW - RC parallel damper
KW - Robustness
KW - Single loop
U2 - 10.1109/TIE.2015.2478738
DO - 10.1109/TIE.2015.2478738
M3 - Journal article
SN - 0278-0046
VL - 63
SP - 926
EP - 936
JO - I E E E Transactions on Industrial Electronics
JF - I E E E Transactions on Industrial Electronics
IS - 2
ER -