DC-bus voltage control of grid-connected voltage source converter by using space vector modulated direct power control under unbalanced network conditions

Lei Xiao, Shoudao Huang, Kaiyuan Lu

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

42 Citationer (Scopus)

Abstract

Unbalanced grid voltage will cause large dc-bus voltage ripple and introduce high harmonic current components on the grid side. This will severely threaten the safety of the grid-connected voltage source converter (VSC) and consequently, affect the healthy operation condition of the load. In this study, a new proportional-integral-resonant (PI-RES) controller-based, space vector modulated direct power control topology is proposed to suppress the dc-bus voltage ripple and in the same time, controlling effectively the instantaneous power of the VSC. A special ac reactive power reference component is introduced in the controller, which is necessary in order to reduce the dc-bus voltage ripple and active power harmonics at the same time. The proposed control topology is implemented in the lab. Simulation and experimental results are provided to validate its performance and the analysis presented in this study.
OriginalsprogEngelsk
TidsskriftIET Power Electronics
Vol/bind6
Udgave nummer5
Sider (fra-til)925-934
Antal sider10
ISSN1755-4535
DOI
StatusUdgivet - 2013

Fingeraftryk

Dyk ned i forskningsemnerne om 'DC-bus voltage control of grid-connected voltage source converter by using space vector modulated direct power control under unbalanced network conditions'. Sammen danner de et unikt fingeraftryk.

Citationsformater