Abstract
This paper investigates a controller that ensures minimum operating dc-link voltage of a back-to-back converter system. The dc-link voltage adapts its reference based on the system state, reference given by an outer loop to the dc-link voltage controller. The operating dc-link voltage should be kept as low
as possible to increase the power conversion efficiency and increase the reliability of converters. The dynamic performance of the proposed controller is investigated by simulations and experiments.
as possible to increase the power conversion efficiency and increase the reliability of converters. The dynamic performance of the proposed controller is investigated by simulations and experiments.
Originalsprog | Engelsk |
---|---|
Titel | Proceedings of the 16th Conference on Power Electronics and Applications, EPE’14-ECCE Europe |
Antal sider | 7 |
Forlag | IEEE Press |
Publikationsdato | 26 aug. 2014 |
DOI | |
Status | Udgivet - 26 aug. 2014 |
Begivenhed | 16th Conference on Power Electronics and Applications, EPE’14-ECCE Europe - Lappeenranta, Finland Varighed: 26 aug. 2014 → 28 aug. 2014 |
Konference
Konference | 16th Conference on Power Electronics and Applications, EPE’14-ECCE Europe |
---|---|
Land/Område | Finland |
By | Lappeenranta |
Periode | 26/08/2014 → 28/08/2014 |