Abstract

Prefabricated extruded hollow-core slabs are preferred building components for floor structures in several countries. It is therefore important to be able to document the fire resistance of these slabs proving fulfilment of standard fire resistance requirements of 60- and 120 minutes found in most national building regulations.

The paper presents a detailed analysis of the mechanisms responsible for the loss of load-bearing capacity of hollow-core slabs when exposed to fire.

Furthermore, it compares theoretical calculation and assessment according to the structural codes with data derived from a standard fire test and from a thorough examination of the comprehensive test documentation available on fire exposed hollow-core slabs.

Mechanisms for loss of load-bearing capacity are clarified, and evidence of the fire resistance is found.

For the first time the mechanisms responsible for loss of load-bearing capacity are identified and test results and calculation approach are for the first time Applied in accordance with each other for assessment of fire resistance of the structure.
Bidragets oversatte titelBrandmodstandsevne for extruderede huldæk
OriginalsprogEngelsk
TidsskriftJournal of Structural Fire Engineering
Vol/bind8
Udgave nummer3
Sider (fra-til)324-336
Antal sider13
ISSN2040-2317
DOI
StatusUdgivet - 2017

Emneord

  • Extruded hollow-core slabs, fire test, standard fire resistance, load-bearing capacity