Wastewater pump systems decompose relatively rapidly compared to other pump systems because of the demanding properties of the pump medium. Only a systematic maintenance of the systems can prevent a significant and continuous decrease of the energy consumption per unit volume pumped (the specific energy). This article presents a method for a continuous supervision of the performance of both the pump and the pipeline in order to maintain the initial specific energy consumption as close as possible to the original value from when the system was commissioned. The method is based on pressure measurements only. The flow is determined indirectly from pressure fluctuations during pump run-up.
Originalsprog | Engelsk |
---|---|
Artikelnummer | 04015048 |
Tidsskrift | Journal of Hydraulic Engineering (Reston) |
Vol/bind | 142 |
Udgave nummer | 2 |
Antal sider | 6 |
ISSN | 0733-9429 |
DOI | |
Status | Udgivet - 2016 |
Emneord
- Wastewater management
- Maintenance
- Pipes
- Pumps
- Efficiency
- Pressure measurements