Abstract
On-state collector-emitter voltage (VCE) is a good indicator to determine the wear-out condition of power device modules. Further, it is a one of the Temperature Sensitive Electrical Parameters (TSEPs) and thus can be used for junction temperature estimation. In this paper, the junction temperature estimation method using on-state VCE for an advanced active power cycling test is proposed. The concept of the advanced power cycling test is explained first. Afterwards the junction temperature estimation method using on-state VCE and current is presented. Further, the method to improve the accuracy of the maximum junction temperature estimation is also proposed. Finally, the validity and effectiveness of the proposed method is confirmed by experimental results.
Originalsprog | Engelsk |
---|---|
Titel | Proceedings of the 2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) |
Antal sider | 7 |
Forlag | IEEE Press |
Publikationsdato | jun. 2015 |
Sider | 2944 - 2950 |
DOI | |
Status | Udgivet - jun. 2015 |
Begivenhed | 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia 2015) - Seoul, Sydkorea Varighed: 1 jun. 2015 → 5 jun. 2015 |
Konference
Konference | 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia 2015) |
---|---|
Land/Område | Sydkorea |
By | Seoul |