Abstrakt

This paper presents the novel design of a Magnetic Lead Screw (MLS) with magnetic thread of Halbach Arrays. The MLS where designed and build, tests indicated a stall force which where 12 % lower than calculated in 3D FE. This is explained by demagnetization of the magnet during stall, the behavior of the demagnetization has been studied and the results from these studies are presented in this paper.
Luk

Detaljer

This paper presents the novel design of a Magnetic Lead Screw (MLS) with magnetic thread of Halbach Arrays. The MLS where designed and build, tests indicated a stall force which where 12 % lower than calculated in 3D FE. This is explained by demagnetization of the magnet during stall, the behavior of the demagnetization has been studied and the results from these studies are presented in this paper.
OriginalsprogEngelsk
Publikationsdatojul. 2015
StatusUdgivet - jul. 2015
Begivenhed - Aachen, Tyskland

Konference

KonferenceLinear Drives for Industry Applications LDIA 2015
LandTyskland
ByAachen
Periode27/07/201529/07/2015