Abstract
The paper proposes a simple but effective model for no-inertia microgrids suitable to represent the instantaneous values of its meaningful electric variables, becoming a useful platform to test innovative control logics and energy management systems. The proposed model is validated against a more detailed microgrid representation implemented in the electromagnetic simulator PSCAD-EMTDC and then against experimental data collected on the University of Genoa testbed facility. Recorded data highlight a good trade-off in matching the results of the proposed model, confirming its suitability to be used for the preliminary testing of new control logics for islanded microgrids.
Originalsprog | Engelsk |
---|---|
Artikelnummer | 8316913 |
Tidsskrift | IEEE Transactions on Sustainable Energy |
Vol/bind | 9 |
Udgave nummer | 4 |
Sider (fra-til) | 1812-1821 |
Antal sider | 10 |
ISSN | 1949-3029 |
DOI | |
Status | Udgivet - okt. 2018 |