Offset rejection for PLL based synchronization in grid-connected converters

Publikation: Forskning - peer reviewKonferenceartikel i proceeding

Standard

Offset rejection for PLL based synchronization in grid-connected converters. / Ciobotaru, Mihai; Teodorescu, Remus; Agelidis, Vassilios.

Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2008: Proceedings. IEEE, 2008. s. 1611-1617.

Publikation: Forskning - peer reviewKonferenceartikel i proceeding

Harvard

Ciobotaru, M, Teodorescu, R & Agelidis, V 2008, 'Offset rejection for PLL based synchronization in grid-connected converters'. i Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2008: Proceedings. IEEE, s. 1611-1617.

APA

Ciobotaru, M., Teodorescu, R., & Agelidis, V. (2008). Offset rejection for PLL based synchronization in grid-connected converters. I Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2008. (s. 1611-1617). IEEE.

CBE

Ciobotaru M, Teodorescu R, Agelidis V. 2008. Offset rejection for PLL based synchronization in grid-connected converters. I Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2008: Proceedings. IEEE. s. 1611-1617.

MLA

Ciobotaru, Mihai, RemusTeodorescu og VassiliosAgelidis "Offset rejection for PLL based synchronization in grid-connected converters". Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2008: Proceedings. IEEE. 2008. 1611-1617.

Vancouver

Ciobotaru M, Teodorescu R, Agelidis V. Offset rejection for PLL based synchronization in grid-connected converters. I Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2008: Proceedings. IEEE. 2008. s. 1611-1617.

Author

Ciobotaru, Mihai; Teodorescu, Remus; Agelidis, Vassilios / Offset rejection for PLL based synchronization in grid-connected converters.

Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2008: Proceedings. IEEE, 2008. s. 1611-1617.

Publikation: Forskning - peer reviewKonferenceartikel i proceeding

Bibtex

@inbook{f0350580017d11de8dc0000ea68e967b,
title = "Offset rejection for PLL based synchronization in grid-connected converters",
publisher = "IEEE",
author = "Mihai Ciobotaru and Remus Teodorescu and Vassilios Agelidis",
year = "2008",
isbn = "978-1-4244-1873-2",
pages = "1611-1617",
booktitle = "Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2008",

}

RIS

TY - GEN

T1 - Offset rejection for PLL based synchronization in grid-connected converters

A1 - Ciobotaru,Mihai

A1 - Teodorescu,Remus

A1 - Agelidis,Vassilios

AU - Ciobotaru,Mihai

AU - Teodorescu,Remus

AU - Agelidis,Vassilios

PB - IEEE

PY - 2008

Y1 - 2008

N2 - Grid-connected converters rely on fast and accurate detection of the phase angle, amplitude and frequency of the utility voltage to guarantee the correct generation of the reference signals. An important issue associated with accurate grid voltage monitoring is the presence of an offset in the measured grid voltage. This voltage offset is typically introduced by the measurements and data conversion processes and causes errors for the estimated parameters of the grid voltage. Accordingly, this paper presents an offset rejection method for grid-connected converters based on a phase-lockedloop (PLL) technique. The offset rejection method relies on the second order generalized integrator (SOGI) having the advantages of a simple implementation independent of the grid frequency and avoidance of filtering delays due to its resonance at the fundamental frequency. Selected experimental results validate the performance and robustness of the proposed offset rejection method.

AB - Grid-connected converters rely on fast and accurate detection of the phase angle, amplitude and frequency of the utility voltage to guarantee the correct generation of the reference signals. An important issue associated with accurate grid voltage monitoring is the presence of an offset in the measured grid voltage. This voltage offset is typically introduced by the measurements and data conversion processes and causes errors for the estimated parameters of the grid voltage. Accordingly, this paper presents an offset rejection method for grid-connected converters based on a phase-lockedloop (PLL) technique. The offset rejection method relies on the second order generalized integrator (SOGI) having the advantages of a simple implementation independent of the grid frequency and avoidance of filtering delays due to its resonance at the fundamental frequency. Selected experimental results validate the performance and robustness of the proposed offset rejection method.

SN - 978-1-4244-1873-2

BT - Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2008

T2 - Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2008

SP - 1611

EP - 1617

ER -