Online Grid Measurement and ENS Detection for PV Inverter Running on Highly Inductive Grid
Publikation: Forskning - peer review › Tidsskriftartikel
Standard
Online Grid Measurement and ENS Detection for PV Inverter Running on Highly Inductive Grid. / Timbus, Adrian Vasile; Teodorescu, Remus; Blaabjerg, Frede; Borup, Uffe.
I: IEEE Power Electronics Letters, Vol. 2, Nr. 3, 2004, s. 77-82.Publikation: Forskning - peer review › Tidsskriftartikel
Harvard
APA
CBE
MLA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - Online Grid Measurement and ENS Detection for PV Inverter Running on Highly Inductive Grid
A1 - Timbus,Adrian Vasile
A1 - Teodorescu,Remus
A1 - Blaabjerg,Frede
A1 - Borup,Uffe
AU - Timbus,Adrian Vasile
AU - Teodorescu,Remus
AU - Blaabjerg,Frede
AU - Borup,Uffe
PB - I E E E
PY - 2004
Y1 - 2004
N2 - Photovoltaic (PV) and other sources of renewable energy are being used increasingly in grid-connected systems, for which stronger power quality requirements are being issued. Continuous grid monitoring should be considered so as to provide safe connections and disconnections from the grid. This letter gives an overview of the methods used for online grid measurement with PV inverters. Emphasis is placed on a method based on the injection of a noncharacteristic harmonic in the grid. Since this injection is regarded as a disturbance for the grid, different issues, i.e., the influence on total harmonic distortion (THD), the accuracy of line impedance measurement and the ENS (German abbreviation of Main Monitoring units with allocated Switching Devices) detection are studied. Laboratory results conducted on an existing PV inverter are presented to demonstrate the behavior of the PV inverter under different grid conditions. Some of the injection parameters are tuned in order to get an accurate measurement of line impedance.
AB - Photovoltaic (PV) and other sources of renewable energy are being used increasingly in grid-connected systems, for which stronger power quality requirements are being issued. Continuous grid monitoring should be considered so as to provide safe connections and disconnections from the grid. This letter gives an overview of the methods used for online grid measurement with PV inverters. Emphasis is placed on a method based on the injection of a noncharacteristic harmonic in the grid. Since this injection is regarded as a disturbance for the grid, different issues, i.e., the influence on total harmonic distortion (THD), the accuracy of line impedance measurement and the ENS (German abbreviation of Main Monitoring units with allocated Switching Devices) detection are studied. Laboratory results conducted on an existing PV inverter are presented to demonstrate the behavior of the PV inverter under different grid conditions. Some of the injection parameters are tuned in order to get an accurate measurement of line impedance.
JO - IEEE Power Electronics Letters
JF - IEEE Power Electronics Letters
SN - 1540-7985
IS - 3
VL - 2
SP - 77
EP - 82
ER -