Abstract

As a popular renewable power generation solution, the Doubly Fed Induction Generator (DFIG) based wind power system may suffer from High Frequency Resonance (HFR) caused by the impedance interaction between the DFIG system and the parallel compensated weak network. A wide frequency band active damping strategy for DFIG system HFR, including a high-pass filter and a virtual resistance, is proposed in this paper. The advantages of this active damping strategy are, 1) no resonance frequency detection unit is required, thus the control complexity can be decreased; 2) no active damping parameters adjustment is needed within certain wide frequency band, thus the robustness of the proposed active damping strategy can be improved. The parameter design of the high-pass filter cutoff frequency and the virtual resistance are theoretically analyzed with the purpose of satisfactory active damping. A 7.5 kW down-scaled experimental setup is built up for the experimental validation of the proposed active damping method.
OriginalsprogEngelsk
TidsskriftI E E E Transactions on Energy Conversion
Vol/bind31
Udgave nummer4
Sider (fra-til)1665-1675
Antal sider11
ISSN0885-8969
DOI
StatusUdgivet - dec. 2016

Fingeraftryk

Dyk ned i forskningsemnerne om 'Wide Frequency Band Active Damping Strategy for DFIG System High Frequency Resonance'. Sammen danner de et unikt fingeraftryk.

Citationsformater