A closed-form formulation for the conformal articulation of metal-on-polyethylene hip prostheses: contact mechanics and sliding distance

Ehsan Askari Renani, Michael Skipper Andersen

Research output: Contribution to journalJournal articleResearchpeer-review

15 Citations (Scopus)
328 Downloads (Pure)

Abstract

Using Hertz contact law results in inaccurate outcomes when applied to the soft conformal hip implants. The finite element method also involves huge computational time and power. In addition, the sliding distance computed using the Euler rotation method does not incorporate tribology of bearing surfaces, contact mechanics and inertia forces. This study, therefore, aimed to develop a nonlinear dynamic model based on the multibody dynamic methodology to predict contact pressure and sliding distance of metal-on-polyethylene hip prosthesis, simultaneously, under normal walking condition. A closed-form formulation of the contact stresses distributed over the articulating surfaces was derived based upon the elastic foundation model, which reduced computational time and cost significantly. Three-dimensional physiological loading and motions, inertia forces due to hip motion and energy loss during contact were incorporated to obtain contact properties and sliding distance. Comparing the outcomes with that available in the literature and a finite element analysis allowed for the validation of our approach. Contours of contact stresses and accumulated sliding distances at different instants of the walking gait cycle were investigated and discussed. It was shown that the contact point at each instant was located within the zone with the corresponding highest accumulated sliding distance. In addition, the maximum contact pressure and area took place at the stance phase with a single support. The stress distribution onto the cup surface also conformed to the contact point trajectory and the physiological loading.

Original languageEnglish
JournalProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Volume232
Issue number12
Pages (from-to)1196-1208
Number of pages13
ISSN0954-4119
DOIs
Publication statusPublished - 1 Dec 2018

Keywords

  • Sliding distance
  • contact mechanics
  • elastic foundation method
  • nonlinear dynamics
  • total hip replacement

Fingerprint

Dive into the research topics of 'A closed-form formulation for the conformal articulation of metal-on-polyethylene hip prostheses: contact mechanics and sliding distance'. Together they form a unique fingerprint.

Cite this