Abstract
In this paper we are presenting the power analysis for thermal awareness of different counters. The technique we are using to do the analysis is based on 28 nm FPGA tech-nique. In this work during implementation on FPGA, we are going to analyze thermal stability of different counters in temperature range of 10oC, 30oC, 60oC, 90oC, 120oC. There is 90.36% reduction in leakage power of divide by 2 counter when we scale down the temperature from 120oC to 10oC and 49.61% reduction in leakage power of LFSR up counter when we scale down the temperature from 120oC to 10oC.
Original language | English |
---|---|
Journal | Gyancity Journal of Engineering and Technology |
Volume | 2 |
Issue number | 2 |
Pages (from-to) | 1 - 8 |
Number of pages | 8 |
ISSN | 2456-0065 |
DOIs | |
Publication status | Published - Jul 2016 |
Keywords
- Thermal Stability
- Counter
- 28nm
- FPGA
- Ambient Temperature
- Junction Temperature
- Leakage Power