Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-type Three-Level Inverter Systems

Uimin Choi, Kyo Beum Lee, Frede Blaabjerg

Research output: Contribution to journalJournal articleResearchpeer-review

226 Citations (Scopus)

Abstract

This paper proposes a new diagnosis method of an open-switch fault and fault-tolerant control strategy for T-type three-level inverter systems. The location of faulty switch can be identified by the average of normalized phase current and the change of the neutral-point voltage. The proposed fault-tolerant strategy is explained by dividing into two cases: the faulty condition of half-bridge switches and the neutral-point switches. The performance of the T-type inverter system improves considerably by the proposed fault tolerant algorithm when a switch fails. The roposed method does not require additional components and complex calculations. Simulation and experimental results verify the feasibility of the proposed fault diagnosis and fault-tolerant control strategy.
Original languageEnglish
JournalI E E E Transactions on Industry Applications
Volume50
Issue number1
Pages (from-to)495-508
Number of pages14
ISSN0093-9994
DOIs
Publication statusPublished - Jan 2014

Keywords

  • Multilevel
  • T-type inverter
  • Fault-tolerance
  • Open-switch fault
  • Reliability

Fingerprint

Dive into the research topics of 'Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-type Three-Level Inverter Systems'. Together they form a unique fingerprint.

Cite this