High Performance Harmonic Isolation By Means of The Single-phase Series Active Filter Employing The Waveform Reconstruction Method

Publication: Research - peer-reviewArticle in proceeding

View graph of relations

This paper proposes the Waveform Reconstruction Method (WRM), which is utilized in the single-phase Series Active Filter's (SAF's) control algorithm, in order to extract the load harmonic voltage component of voltage harmonic type single-phase diode rectifier loads. Employing WRM and the line current sampling delay reduction method (SDRM), a single-phase SAF compensated system provides higher harmonic isolation performance and higher stability margins compared to the system using conventional synchronous reference frame based methods. The analytical, simulation, and experimental studies of a 2.5 kW single-phase SAF compensated system prove the theory.
Original languageEnglish
TitleProceedings of the IEEE Energy Conversion and Expo 2009
Number of pages8
PublisherIEEE
Publication date2009
Pages1451-1458
ISBN (electronic)978-1-4244-2893-9
DOIs
StatePublished

Conference

ConferenceIEEE Energy Conversion and Expo 2009 - ECCE 09
LandUnited States
BySan Jose, California
Periode20-09-0924-09-09

Keywords

  • Harmonic, Harmonic extraction, Isolation, Power quality, Rectifier, Series active filter