Abstract
In this paper the triple pulse testing method and circuit for power loss characterization of power modules is introduced. The proposed test platform is able to accurately characterize both the switching and conduction losses of power modules in a single automated process. A configuration of a half bridge is tested by making a sweep of the junction temperature, dc-link voltage, and current for a given gate drive and dc-bus setup. Test results are presented for a 1700 V 1400 A IGBT power module.
Original language | English |
---|---|
Title of host publication | Proceedings of the 2015 17th European Conference on Power Electronics and Applications (EPE'15-ECCE Europe) |
Number of pages | 7 |
Place of Publication | Geneva |
Publisher | IEEE Press |
Publication date | Sept 2015 |
Pages | 1-7 |
DOIs | |
Publication status | Published - Sept 2015 |
Event | 17th European Conference on Power Electronics and Applications, EPE-ECCE Europe 2015 - Centre International de Conférence Genève (CICG), 17 rue Varembé CH . 1211 Genève 20, Geneva, Switzerland Duration: 8 Sept 2015 → 10 Sept 2015 |
Conference
Conference | 17th European Conference on Power Electronics and Applications, EPE-ECCE Europe 2015 |
---|---|
Location | Centre International de Conférence Genève (CICG), 17 rue Varembé CH . 1211 Genève 20 |
Country/Territory | Switzerland |
City | Geneva |
Period | 08/09/2015 → 10/09/2015 |
Keywords
- Characterization
- Switching losses
- Conduction losses
- Efficiency