Measurement of low-frequency noise in rooms

Steffen Pedersen, Henrik Møller, Kerstin Persson-Waye, Søren Krarup Olesen

Research output: Contribution to book/anthology/report/conference proceedingArticle in proceedingResearch

1 Citation (Scopus)

Abstract

Measurement of low-frequency noise in rooms is problematic due to standing wave patterns. The spatial variation in the sound pressure level can typically be as much as 20-30 dB. For assessment of annoyance from low-frequency noise in dwellings, it is important to measure a level close to the highest level present in a room, rather than a room average level. In order to ensure representative noise measurements, different positions were investigated based on theoretical considerations and observations from numerical room simulations. In addition measurements were performed in three different rooms. The sound pressure level was measured 1) in three-dimensional corners and 2) according to current Swedish and Danish measurement methods. Furthermore, the entire sound pressure distributions were measured by scanning. The Swedish and Danish measurement methods include a corner measurement position to ensure representative high levels. However, this position has some distance to the walls, and may still be subject to modal influence. It was confirmed by the measurements that the positions from especially the Danish measurement method may not effectively serve their purpose. It is suggested that four three-dimensional corners are used for indoor measurement of low-frequency noise.
Original languageEnglish
Title of host publicationProceedings of Inter-Noise 2006 : The 35th International Congress and Exposition on Noise Control Engineering
Number of pages10
PublisherInstitute of Noise Control Engineering of the USA, Inc.
Publication date2006
Publication statusPublished - 2006
EventInter-Noise 2006 - Honolulu, Hawaii, United States
Duration: 3 Dec 20066 Dec 2006
Conference number: 35

Conference

ConferenceInter-Noise 2006
Number35
Country/TerritoryUnited States
CityHonolulu, Hawaii
Period03/12/200606/12/2006

Bibliographical note

CD-ROM Paper no. 425.
Abstract no. 566 in Book of Abstracts

Fingerprint

Dive into the research topics of 'Measurement of low-frequency noise in rooms'. Together they form a unique fingerprint.
  • Measurement of low-frequency sound in rooms

    Pedersen, S., Møller, H., Persson-Waye, K. & Olesen, S. K.

    19/05/201031/12/2017

    Project: Research

Cite this