Leakage current analysis of single-phase transformer-less grid-connected PV inverters

Lin Ma, Tamas Kerekes, Remus Teodorescu, Fen Tang, Xinmin Jin, Yibin Tong, Jingzhe Liang

Research output: Contribution to book/anthology/report/conference proceedingArticle in proceedingResearchpeer-review

6 Citations (Scopus)

Abstract

Transformer-less string PV inverter is getting more and more widely utilized due to its higher efficiency, smaller volume and weight. However, without the galvanic isolation, the leakage current limitation and operation safety became the key issues of transformer-less inverters. This paper simplifies the leakage current generation circuit model and presents a leakage current estimation method both in real time and frequency domain. It shows that the leakage current is related to the circuit stray parameters, output filter and common mode voltage. Furthermore, with the proposed analysis method, the leakage current generation of H-bridge with different modulation methods and HERIC inverter are discussed individually. At last, the presented method has been verified via simulation.
Original languageEnglish
Title of host publicationProceedings of the 41st Annual Conference of the IEEE Industrial Electronics Society : IECON 2015
Number of pages6
PublisherIEEE Press
Publication date2016
Pages887-892
Article number7392211
ISBN (Print)978-1-4799-1761-7
ISBN (Electronic)978-1-4799-1762-4
DOIs
Publication statusPublished - 2016
Event41st Annual Conference of the IEEE Industrial Electronics Society, IECON 2015 - Yokohama, Japan
Duration: 9 Nov 201512 Nov 2015

Conference

Conference41st Annual Conference of the IEEE Industrial Electronics Society, IECON 2015
Country/TerritoryJapan
CityYokohama
Period09/11/201512/11/2015
SponsorIEEE Industrial Electonics Society (IES)

Keywords

  • Common mode leakage current
  • Common mode voltage
  • Grid-connected photovoltaic inverter
  • Transformer-less

Fingerprint

Dive into the research topics of 'Leakage current analysis of single-phase transformer-less grid-connected PV inverters'. Together they form a unique fingerprint.

Cite this