Model predictive control methods of leakage current elimination for a three-level T-type transformerless PV inverter

Xiaodong Wang, Jianxiao Zou*, Lan Ma, Jiancheng Zhao, Chuan Xie, Kai Li, Lexuan Meng, Josep M. Guerrero

*Corresponding author for this work

Research output: Contribution to journalJournal articleResearchpeer-review

44 Citations (Scopus)

Abstract

This study presents finite control set model predictive control (FCS-MPC) methods to eliminate leakage current for a three-level T-type transformerless photovoltaic (PV) inverter without any modification on topology or any hardware changes. The proposed FCS-MPC methods are capable of eliminating the leakage current in the transformerless PV system by applying the defined candidate voltage vector (VV) combinations with only six medium and one zero VVs (6MV1Z) or three large and three small VVs, which generate constant common-mode voltage to perform the optimisation in every control period. With fewer VVs used for the optimisation, the computational burden can be significantly reduced. Furthermore, comparative analysis is performed to show that among these proposed methods, the 6MV1Z method can achieve satisfactory performances in both grid current tracking and neutral point potentials balance control even with less number of candidate VVs, which exhibits the FCS-MPC as an alternative control strategy to be used in the grid-connected transformerless PV system. Finally, experiments are performed to validate the analysis and the effectiveness of the proposed methods.
Original languageEnglish
JournalIET Power Electronics
Volume11
Issue number8
Pages (from-to)1492-1498
Number of pages7
ISSN1755-4535
DOIs
Publication statusPublished - Jul 2018

Fingerprint

Dive into the research topics of 'Model predictive control methods of leakage current elimination for a three-level T-type transformerless PV inverter'. Together they form a unique fingerprint.

Cite this