Permanent Magnet Flux Online Estimation Based on Zero-Voltage Vector Injection Method

Ge Xie, Kaiyuan Lu, Dwivedi Sanjeet Kumar, Rosholm Jesper Riber, Weimin Wu

Research output: Contribution to journalLetterpeer-review

20 Citations (Scopus)

Abstract

In this paper, a simple signal injection method is proposed for sensorless control of PMSM at low speed, which ideally requires one voltage vector only for position estimation. The proposed method is easy to implement resulting in low computation burden. No filters are needed for extracting the high frequency current signals for position estimation. The use of Low-Pass Filters (LPFs) in the current control loop to filter out the fundamental current component is not necessary. Therefore, the control bandwidth of the inner current control loop may not need to be sacrificed. The proposed method may also be further developed to inject two opposite voltage vectors to reduce the effects of inverter voltage error on the position estimation accuracy. The effectiveness of the proposed method is demonstrated by comparing with other sensorless control method. Theoretical analysis and experimental results are given for validating the proposed new sensorless control method.
Original languageEnglish
JournalI E E E Transactions on Power Electronics
Volume30
Issue number12
Pages (from-to)6506 - 6509
Number of pages4
ISSN0885-8993
DOIs
Publication statusPublished - Dec 2015

Keywords

  • Filter-free
  • High bandwidth
  • Injection
  • Inverter voltage error
  • Low-speed range
  • Permanent-magnet synchronous machine (PMSM)
  • Sensorless control
  • Voltage

Fingerprint

Dive into the research topics of 'Permanent Magnet Flux Online Estimation Based on Zero-Voltage Vector Injection Method'. Together they form a unique fingerprint.

Cite this