Series Resistance Monitoring for Photovoltaic Modules in the Vicinity of MPP

Dezso Sera

Research output: Contribution to book/anthology/report/conference proceedingArticle in proceedingResearchpeer-review

Abstract

Faults and performance deterioration issues related to increases of the series resistance in PV modules or arrays are one of the most common causes to decrease the energy yield of photovoltaic installations. Therefore, the early detection of such failure types is very important in order to minimize the time period with reduced power production. This paper focuses on the estimation of series resistance of flat silicone PV panels or arrays during operation, in the vicinity of their MPP. The method presented in this paper helps to detect failures by monitoring
changes in the panel’s or array’s series resistance, compared to a reference value that can be determined either by a measurement in controlled conditions, or using datasheet parameters. The method is based on the measurement of the slope of the I-V curve at a fixed distance from the short-circuit current.
Original languageEnglish
Title of host publicationProceedings of the 25th European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC)
Number of pages5
PublisherETA-Renewable Energies and WIP-Renewable Energies
Publication dateSept 2010
Pages4506-4510
ISBN (Print)3-936338-26-4
DOIs
Publication statusPublished - Sept 2010
Event25th European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC) - Valencia, Spain