• Pontoppidanstræde 111, 1-002

    9220 Aalborg Ø

    Danmark

20012020
Hvis du har foretaget ændringer i Pure, vil de snart blive vist her.

Publikationer 2001 2020

Filter
Paper uden forlag/tidsskrift
2017

Scale model test on a novel 400 kV double-circuit composite pylon

Wang, Q., Bak, C. L., Silva, F. M. F. D. & Skouboe, H., jun. 2017. 5 s.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskningpeer review

Åben adgang
Shielding
Lightning
Networks (circuits)
Composite materials
Overhead lines
2014
2 Citationer (Scopus)

Comparison of field Measurements and EMT Simulation results on a multi-level STATCOM for grid integration of London Array wind power plant

Glasdam, J., Kocewiak, Ł. H., Hjerrild, J., Bak, C. L. & Zeni, L., 1 jan. 2014.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskningpeer review

Wind power
Power plants
Static converters
Harmonic distortion
Turbogenerators
2 Citationer (Scopus)

Online travelling wave-based fault location on crossbonded AC cables in underground transmission systems

Jensen, C. F., Bak, C. L. & Gudmundsdottir, U. S., 1 jan. 2014.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskningpeer review

Electric fault location
Cables
Electromagnetic wave propagation
Offshore wind farms
Wavelet transforms
2013

Analysis of Statistical Distributions of Energization Overvoltages of EHV Cables

Ohno, T., Ametani, A., Bak, C. L., Wiechowski, W. & K. Sørensen, T., 2013. 7 s.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskningpeer review

Overhead lines
Cables
Insulation

Online fault location on AC cables in underground transmission systems using screen currents

Jensen, C. F., Nanayakkara, O. M. K. K., Rajapakse, A., Gudmundsdottir, U. S. & Bak, C. L., 2013. 6 s.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskningpeer review

Electric fault location
Cables
Offshore wind farms
Wavelet transforms
Inspection
2011
1 Citation (Scopus)

Derivation of Theoretical Formulas of Sequence Currents on Underground Cable System

Ohno, T., Ametani, A. & Bak, C. L., 2011. 6 s.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskning

Underground cables
Cables
2010
10 Citationer (Scopus)
1422 Downloads (Pure)

Wind Farm Structures’ Impact on Harmonic Emission and Grid Interaction

Kocewiak, L. H., Hjerrild, J. & Bak, C. L., apr. 2010. 8 s.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskning

Åben adgang
Fil
Onshore wind farms
Offshore wind farms
2007
1258 Downloads (Pure)

Transient electromagnetic simulations of substation earth grid for improving lightning withstand performance of a large power transformer

Bak, C. L., Einarsdottir, K. E., Andresson, E., M. Rasmussen, J., Lykkegaard, J. & Wiechowski, W. T., 2007. 7 s.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskningpeer review

Åben adgang
Fil
Overhead lines
Bushings
Power transformers
Electric grounding
Lightning
2006
1126 Downloads (Pure)

Hybrid power filter with reduced inverter power rating

Kedra, B., Krzeszowiak, T., Asiminioaei, L., Wiechowski, W. T. & Bak, C. L., 2006.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskningpeer review

Åben adgang
Fil
2005
8 Citationer (Scopus)
4095 Downloads (Pure)

Harmonic Domain Modeling of a Distribution System Using the DIgSILENT PowerFactory Software

Wasilewski, J., Wiechowski, W. T. & Bak, C. L., 2005. 7 s.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskningpeer review

Åben adgang
Fil
Reactive power
Mathematical operators
Computer systems
Computer simulation
131 Downloads (Pure)

Measurements of the Distorted No-Load Current of a 20/60kV, 6MVA Power Transformer

Søgaard, K., Wiechowski, W. T. & Bak, C. L., 2005.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskningpeer review

Fil
73 Downloads (Pure)

Overhead line audible noise measurements and calculation model for snow and frosty mist

Bak, C. L., Mikkelsen, S. D. & Jensen, C., 2005. 6 s.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskning

Åben adgang
Fil

Transformer Core Nonlinearities Modelled in Harmonic Domain

Wiechowski, W. T., Bak-Jensen, B., Bak, C. L., Lykkegaard, J. & Pöller, M., 2005.

Publikation: Konferencebidrag uden forlag/tidsskriftPaper uden forlag/tidsskriftForskningpeer review