Abstract
A new parameters identification method for induction machine electrical faults detection is presented in this paper. Typical evolutive faults like: phase resistance increase caused by poor contacts, turn-to-turn shortcircuits, unbalanced supply voltages, magnetic circuit ageing and squirrel-cage bar rupture, are taken into consideration. A triphase abc frame it wc, taken into consideration for real phase parameters identification. In order to provide the electrical parameters, an identification technique based on currents, voltages and speed acquisition during transients (e.g. starting-up) has been developed on a portable acquisition and post-processing system. The system can be successfully applied for both periodical preventive maintenance and electrical parameters verification of repaired induction machines.
Originalsprog | Engelsk |
---|---|
Tidsskrift | OPTIM 1998 - Proceedings of the 6th International Conference on Optimization of Electrical and Electronic Equipments |
Sider (fra-til) | 567-572 |
Antal sider | 6 |
DOI | |
Status | Udgivet - jan. 1998 |
Udgivet eksternt | Ja |
Begivenhed | 6th International Conference on Optimization of Electrical and Electronic Equipments, OPTIM 1998 - Brasov, Rumænien Varighed: 14 maj 1998 → 15 maj 1998 |
Konference
Konference | 6th International Conference on Optimization of Electrical and Electronic Equipments, OPTIM 1998 |
---|---|
Land/Område | Rumænien |
By | Brasov |
Periode | 14/05/1998 → 15/05/1998 |