A validation study on muscle activity prediction of a lower limb musculoskeletal model using EMG during normal walking

A. D. Wibawa, N. Verdonschot, J. G M Burgerhof, I. K E Purnama, M. S. Andersen, J. P K Halbertsma, R. L. Diercks, G. J. Verkerke

Publikation: Bidrag til bog/antologi/rapport/konference proceedingKonferenceartikel i proceedingForskningpeer review

4 Citationer (Scopus)

Abstract

This study focused on validating muscle activities predicted by the a Lower Limb musculoskeletal model of AnyBody Modeling System (AMS) against measured muscle activity (EMG) from ten healthy subjects who performed a normal walking task. The GaitLowerExtremity Model (GLEM) of AMS was used in this study. Eight EMG electrodes measured the activity of eight muscles of the right leg: Vastus Medialis, Vastus Lateralis, Rectus Femoris, Semitendinosus, Biceps Femoris, Gastrocnemius Medialis and Lateralis and Tibialis Anterior. Four different thresholds were applied on both curves (predicted and measured muscle activity): 10%, 25%, 35% and 45% of the mean of the graph threshold (MGT) before they were being compared quantitatively in the same threshold level. Number of onset and offset of muscle activity were used to quantify the level of agreement. Visual inspection showed good agreement between EMG and predicted muscle activity. In general, for all parameters the 45 % MGT showed the best agreement compared to the other MGT. For the number of onset and offset, two muscles showed fair agreement and four muscles showed slight agreement. This first attempt in a quantitative point of view showed that 6 muscles showed a slight positive agreement out of 8 in both variables number of onset and offset. The differences between AMS and EMG patterns can be attributed to the nature of the modeling process such as assumption and simplification, and possible inaccuracy of determining knee kinetic data during motion.

OriginalsprogEngelsk
TitelProceedings 2013 3rd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI - BME)
Antal sider5
ForlagIEEE Press
Publikationsdato1 jan. 2013
Sider260-264
Artikelnummer6698504
ISBN (Trykt)978-­1-­4799-­1650-­4
DOI
StatusUdgivet - 1 jan. 2013
Begivenhed2013 3rd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering - Institut Teknologi Bandung, Bandung, Indonesien
Varighed: 7 nov. 20138 nov. 2013
Konferencens nummer: 3

Konference

Konference2013 3rd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering
Nummer3
LokationInstitut Teknologi Bandung
Land/OmrådeIndonesien
ByBandung
Periode07/11/201308/11/2013

Fingeraftryk

Dyk ned i forskningsemnerne om 'A validation study on muscle activity prediction of a lower limb musculoskeletal model using EMG during normal walking'. Sammen danner de et unikt fingeraftryk.

Citationsformater