Age-optimized cut-off values for pubofemoral distances in screening for hip dysplasia

H-C. Husum*, M. B. Hellfritzsch, R. D. Maimburg, B. Møller-Madsen, M. Henriksen, N. Lapitskaya, S. Kold, O. Rahbek

*Kontaktforfatter

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

1 Citationer (Scopus)
15 Downloads (Pure)

Abstract

AIMS: To establish cut-off values for lateral pubofemoral distance (PFD) measurements for detecting hip dysplasia in early (four days) and standard care (six weeks) screening for developmental dysplasia of the hip (DDH).

METHODS: All newborns, during a one-year period (October 2021 to October 2022), were offered a PFD ultrasound (US) examination in addition to the existing screening programme for DDH. Newborns who were referred for standard care hip US, suspected for DDH, received a secondary PFD US examination in conjunction with the standard care Graf/Harcke hip US examination. Receiver operating characteristic curves and empirically optimal cut-off values were calculated with a true positive defined as a Graf type ≥ IIc hip.

RESULTS: We included 2,735 newborns, of whom 758 received both early PFD hip US and standard care Graf/Harcke hip US. For early (four days) PFD screening, the optimal cut-off point was calculated to be 6.2 mm (95% CI 4.7 to 7.7) producing a sensitivity of 80% (95% CI 55% to 100%) and a specificity of 87% (86% to 89%). For PFD screening performed at standard care (six weeks) hip US, the optimal cut-off point was calculated to be 5.6 mm (95% CI 4.9 to 6.3) producing a sensitivity of 100% (95% CI 100% to 100%) and a specificity of 96% (95% CI 95% to 97%).

CONCLUSION: PFD US screening produces a high degree of both sensitivity and specificity for detecting DDH. Age-specific cut-off values should be used to heighten the accuracy of PFD US screening.

OriginalsprogEngelsk
TidsskriftBone & joint open
Vol/bind6
Udgave nummer2
Sider (fra-til)119-125
Antal sider7
ISSN2633-1462
DOI
StatusUdgivet - 3 feb. 2025