Control of Permanent Magnet Synchronous Generator for large wind turbines

Cristian Busca, Ana-Irina Stan, Tiberiu Stanciu, Daniel Ioan Stroe

Publikation: Bidrag til bog/antologi/rapport/konference proceedingKonferenceartikel i proceedingForskningpeer review

38 Citationer (Scopus)

Resumé

Direct Torque Control (DTC) and Field Oriented Control (FOC) are the most dominant control strategies used in generators for wind turbines. In this paper both control methods were implemented on a Permanent Magnet Synchronous Generator (PMSG). The variable speed wind turbine with full scale power converter topology was chosen for design. Parameters from a 2 MW wind turbine were used for system modeling. All the components of the wind turbine system (WTS), except the DC-link and the grid site converter were implemented in MATLAB/Simulink. The pitch controller was used to limit the output power produced by the turbine. DTC and FOC strategies, using SVM were used to control the generator rotor speed. The performance of the two control strategies were compared after different tests have been carried out.
OriginalsprogEngelsk
TitelProceedings of the IEEE International Symposium on Industrial Electronics, ISIE 2010
Antal sider6
ForlagIEEE Press
Publikationsdato2010
Sider3871-3876
ISBN (Trykt)978-1-4244-6390-9
DOI
StatusUdgivet - 2010
Begivenhed2010 IEEE International Symposium on Industrial Electronics, ISIE 2010 - Bari, Italien
Varighed: 4 jul. 20107 jul. 2010

Konference

Konference2010 IEEE International Symposium on Industrial Electronics, ISIE 2010
LandItalien
ByBari
Periode04/07/201007/07/2010
SponsorThe Institute of Electrical and Electronics Engineers (IEEE), IEEE Industrial Electronics Society (IES), IEEE Control Systems Society (CSS), Society of Instrument and Control Engineers (SICE-Japan), Polytechnic University of Bari

Fingerprint

Synchronous generators
Wind turbines
Permanent magnets
Torque control
Power converters
MATLAB
Turbines
Rotors
Topology
Controllers
Vector control (Electric machinery)

Citer dette

Busca, C., Stan, A-I., Stanciu, T., & Stroe, D. I. (2010). Control of Permanent Magnet Synchronous Generator for large wind turbines. I Proceedings of the IEEE International Symposium on Industrial Electronics, ISIE 2010 (s. 3871-3876). IEEE Press. https://doi.org/10.1109/ISIE.2010.5637628
Busca, Cristian ; Stan, Ana-Irina ; Stanciu, Tiberiu ; Stroe, Daniel Ioan. / Control of Permanent Magnet Synchronous Generator for large wind turbines. Proceedings of the IEEE International Symposium on Industrial Electronics, ISIE 2010 . IEEE Press, 2010. s. 3871-3876
@inproceedings{e195a44437fa48ab8a759d3062eeacda,
title = "Control of Permanent Magnet Synchronous Generator for large wind turbines",
abstract = "Direct Torque Control (DTC) and Field Oriented Control (FOC) are the most dominant control strategies used in generators for wind turbines. In this paper both control methods were implemented on a Permanent Magnet Synchronous Generator (PMSG). The variable speed wind turbine with full scale power converter topology was chosen for design. Parameters from a 2 MW wind turbine were used for system modeling. All the components of the wind turbine system (WTS), except the DC-link and the grid site converter were implemented in MATLAB/Simulink. The pitch controller was used to limit the output power produced by the turbine. DTC and FOC strategies, using SVM were used to control the generator rotor speed. The performance of the two control strategies were compared after different tests have been carried out.",
author = "Cristian Busca and Ana-Irina Stan and Tiberiu Stanciu and Stroe, {Daniel Ioan}",
year = "2010",
doi = "10.1109/ISIE.2010.5637628",
language = "English",
isbn = "978-1-4244-6390-9",
pages = "3871--3876",
booktitle = "Proceedings of the IEEE International Symposium on Industrial Electronics, ISIE 2010",
publisher = "IEEE Press",

}

Busca, C, Stan, A-I, Stanciu, T & Stroe, DI 2010, Control of Permanent Magnet Synchronous Generator for large wind turbines. i Proceedings of the IEEE International Symposium on Industrial Electronics, ISIE 2010 . IEEE Press, s. 3871-3876, 2010 IEEE International Symposium on Industrial Electronics, ISIE 2010, Bari, Italien, 04/07/2010. https://doi.org/10.1109/ISIE.2010.5637628

Control of Permanent Magnet Synchronous Generator for large wind turbines. / Busca, Cristian; Stan, Ana-Irina; Stanciu, Tiberiu; Stroe, Daniel Ioan.

Proceedings of the IEEE International Symposium on Industrial Electronics, ISIE 2010 . IEEE Press, 2010. s. 3871-3876.

Publikation: Bidrag til bog/antologi/rapport/konference proceedingKonferenceartikel i proceedingForskningpeer review

TY - GEN

T1 - Control of Permanent Magnet Synchronous Generator for large wind turbines

AU - Busca, Cristian

AU - Stan, Ana-Irina

AU - Stanciu, Tiberiu

AU - Stroe, Daniel Ioan

PY - 2010

Y1 - 2010

N2 - Direct Torque Control (DTC) and Field Oriented Control (FOC) are the most dominant control strategies used in generators for wind turbines. In this paper both control methods were implemented on a Permanent Magnet Synchronous Generator (PMSG). The variable speed wind turbine with full scale power converter topology was chosen for design. Parameters from a 2 MW wind turbine were used for system modeling. All the components of the wind turbine system (WTS), except the DC-link and the grid site converter were implemented in MATLAB/Simulink. The pitch controller was used to limit the output power produced by the turbine. DTC and FOC strategies, using SVM were used to control the generator rotor speed. The performance of the two control strategies were compared after different tests have been carried out.

AB - Direct Torque Control (DTC) and Field Oriented Control (FOC) are the most dominant control strategies used in generators for wind turbines. In this paper both control methods were implemented on a Permanent Magnet Synchronous Generator (PMSG). The variable speed wind turbine with full scale power converter topology was chosen for design. Parameters from a 2 MW wind turbine were used for system modeling. All the components of the wind turbine system (WTS), except the DC-link and the grid site converter were implemented in MATLAB/Simulink. The pitch controller was used to limit the output power produced by the turbine. DTC and FOC strategies, using SVM were used to control the generator rotor speed. The performance of the two control strategies were compared after different tests have been carried out.

U2 - 10.1109/ISIE.2010.5637628

DO - 10.1109/ISIE.2010.5637628

M3 - Article in proceeding

SN - 978-1-4244-6390-9

SP - 3871

EP - 3876

BT - Proceedings of the IEEE International Symposium on Industrial Electronics, ISIE 2010

PB - IEEE Press

ER -

Busca C, Stan A-I, Stanciu T, Stroe DI. Control of Permanent Magnet Synchronous Generator for large wind turbines. I Proceedings of the IEEE International Symposium on Industrial Electronics, ISIE 2010 . IEEE Press. 2010. s. 3871-3876 https://doi.org/10.1109/ISIE.2010.5637628