Device-detected atrial high rate episodes and the risk of stroke/thrombo-embolism and atrial fibrillation incidence: a systematic review and meta-analysis

Marco Vitolo, Jacopo F Imberti, Anna Maisano, Alessandro Albini, Niccolò Bonini, Anna Chiara Valenti, Vincenzo L Malavasi, Marco Proietti, Jeff S Healey, Gregory Yh Lip, Giuseppe Boriani*

*Kontaktforfatter

Publikation: Bidrag til tidsskriftReview (oversigtsartikel)peer review

32 Citationer (Scopus)

Abstract

BACKGROUND: Atrial High Rate Episodes (AHRE) are asymptomatic atrial tachy-arrhythmias detected through continuous monitoring with a cardiac implantable electronic device. The risks of stroke/Thromboembolic (TE) events and incident clinical Atrial Fibrillation (AF) associated with AHRE varies markedly.

OBJECTIVES: To assess the relationship between AHRE and TE events, and between AHRE and incident clinical AF.

METHODS: This systematic review and meta-analysis was conducted following the PRISMA recommendations. PubMed, Scopus, and Google Scholar were searched from inception to 18/02/2021 for studies reporting TE events and incident clinical AF in patients with AHRE, as compared with patients without.

RESULTS: Ten out of 8081 records fulfilled the inclusion criteria, for a total of 37 266 patients. Seven out of ten studies excluded patients with prior history of clinical AF (4961 patients), embracing the most recent definition of AHRE. The risk ratio (RR) for TE events in AHRE patients was 2.13 (95% CI: 1.53-2.95, I2: 0%). The incidence of clinical AF was reported in four studies excluding patients with a history of clinical AF (3574 patients). The RR for incident clinical AF was 3.34 (95%CI: 1.89-5.90, I2: 73%).

CONCLUSIONS: AHRE are significantly associated with systemic thromboembolism and incident clinical AF. Further studies are needed to improve patients' risk stratification and management.

OriginalsprogEngelsk
TidsskriftEuropean Journal of Internal Medicine
Vol/bind92
Sider (fra-til)100-106
Antal sider7
ISSN0953-6205
DOI
StatusUdgivet - okt. 2021

Bibliografisk note

Copyright © 2021. Published by Elsevier B.V.

Fingeraftryk

Dyk ned i forskningsemnerne om 'Device-detected atrial high rate episodes and the risk of stroke/thrombo-embolism and atrial fibrillation incidence: a systematic review and meta-analysis'. Sammen danner de et unikt fingeraftryk.