Abstract

The exposure by personal music players may in future be
displayed to users, as described in the current draft of EN
50332-3. The suggested procedure includes a weighting of
the electrical output voltages of the music player and
does not include the significance of the earphone sensitivity.
It doesn't include the weighting principles necessary
for sound sources close to the ears either, which
constitutes an inverse head-related transfer function for
either free- or diffuse field. The purpose of the present
study is to assess the uncertainties in the dose estimate
determined this way. Measurements for 20 earphones are
included, and free- and diffuse field equivalent levels
determined according to ISO 11904-2.
OriginalsprogEngelsk
TitelProceedings of AES 58th International Conference on Music Induced Hearing Disorders
Antal sider7
ForlagAudio Engineering Society
Publikationsdato2015
Artikelnummer6-2
ISBN (Elektronisk)978-1-942220-04-6
StatusUdgivet - 2015
BegivenhedAES 58th International Conference on Music Induced Hearing Disorders - AKKC, Aalborg, Danmark
Varighed: 28 jun. 201530 jun. 2015
Konferencens nummer: 58

Konference

KonferenceAES 58th International Conference on Music Induced Hearing Disorders
Nummer58
LokationAKKC
Land/OmrådeDanmark
ByAalborg
Periode28/06/201530/06/2015

Fingeraftryk

Dyk ned i forskningsemnerne om 'Dose estimate by personal music players based on weighted output voltage'. Sammen danner de et unikt fingeraftryk.

Citationsformater