Effect of Current Density, Temperature and Pressure on Proton Exchange Membrane Electrolyser Stack

Na Li*, Samuel Simon Araya, Søren Knudsen Kær

*Kontaktforfatter

Publikation: Bidrag til tidsskriftKonferenceartikel i tidsskriftForskningpeer review

Abstract

This study investigates the effects of operating
parameters of different current density, temperature and pressure on
the performance of a proton exchange membrane (PEM) water
electrolysis stack. A 7-cell PEM water electrolysis stack was
assembled and tested under different operation modules. The voltage
change and polarization curves under different test conditions, namely
current density, temperature and pressure, were recorded. Results
show that higher temperature has positive effect on overall stack
performance, where temperature of 80 ℃ improved the cell
performance greatly. However, the cathode pressure and current
density has little effect on stack performance.
OriginalsprogEngelsk
TidsskriftInternational Journal of Energy and Power Engineering
Vol/bind15
Udgave nummer1
Antal sider4
ISSN2326-957X
StatusUdgivet - 2021

Fingeraftryk

Dyk ned i forskningsemnerne om 'Effect of Current Density, Temperature and Pressure on Proton Exchange Membrane Electrolyser Stack'. Sammen danner de et unikt fingeraftryk.

Citationsformater