Estimation of Radiation Limit from a Huygens' Box under Non-Free-Space Conditions

Ondrej Franek, Morten Sørensen, Ivan Bonev Bonev, Hans Ebert, Gert Frølund Pedersen

Publikation: Bidrag til bog/antologi/rapport/konference proceedingKonferenceartikel i proceedingForskningpeer review

190 Downloads (Pure)

Resumé

The recently studied Huygens' box method has difficulties when radiation of an electronic module is to be determined under non-free-space conditions, i.e. with an enclosure. We propose an estimate on radiation limit under such conditions based only on the Huygens' box data from free-space measurements. Numerical experiment shows that the limit is valid everywhere except the resonance frequencies. Consequently, it is argued that knowledge of the inner structure of the module is in fact necessary also for the limit estimation.
OriginalsprogEngelsk
Titel2013 International Conference on Electromagnetics in Advanced Applications (ICEAA)
Antal sider3
ForlagIEEE
Publikationsdato2013
Sider1210-1212
ISBN (Trykt)978-1-4673-5705-0
DOI
StatusUdgivet - 2013
Begivenhed2013 International Conference on Electromagnetics in Advanced Applications (ICEAA) - Torino, Italien
Varighed: 9 sep. 201313 sep. 2013

Konference

Konference2013 International Conference on Electromagnetics in Advanced Applications (ICEAA)
LandItalien
ByTorino
Periode09/09/201313/09/2013

Fingerprint

boxes
radiation
electronic modules
enclosure
modules
estimates

Citer dette

Franek, O., Sørensen, M., Bonev, I. B., Ebert, H., & Pedersen, G. F. (2013). Estimation of Radiation Limit from a Huygens' Box under Non-Free-Space Conditions. I 2013 International Conference on Electromagnetics in Advanced Applications (ICEAA) (s. 1210-1212). IEEE. https://doi.org/10.1109/ICEAA.2013.6632438
Franek, Ondrej ; Sørensen, Morten ; Bonev, Ivan Bonev ; Ebert, Hans ; Pedersen, Gert Frølund. / Estimation of Radiation Limit from a Huygens' Box under Non-Free-Space Conditions. 2013 International Conference on Electromagnetics in Advanced Applications (ICEAA). IEEE, 2013. s. 1210-1212
@inproceedings{b85efd0dd4034be1a259a13f7201d9d1,
title = "Estimation of Radiation Limit from a Huygens' Box under Non-Free-Space Conditions",
abstract = "The recently studied Huygens' box method has difficulties when radiation of an electronic module is to be determined under non-free-space conditions, i.e. with an enclosure. We propose an estimate on radiation limit under such conditions based only on the Huygens' box data from free-space measurements. Numerical experiment shows that the limit is valid everywhere except the resonance frequencies. Consequently, it is argued that knowledge of the inner structure of the module is in fact necessary also for the limit estimation.",
author = "Ondrej Franek and Morten S{\o}rensen and Bonev, {Ivan Bonev} and Hans Ebert and Pedersen, {Gert Fr{\o}lund}",
year = "2013",
doi = "10.1109/ICEAA.2013.6632438",
language = "English",
isbn = "978-1-4673-5705-0",
pages = "1210--1212",
booktitle = "2013 International Conference on Electromagnetics in Advanced Applications (ICEAA)",
publisher = "IEEE",
address = "United States",

}

Franek, O, Sørensen, M, Bonev, IB, Ebert, H & Pedersen, GF 2013, Estimation of Radiation Limit from a Huygens' Box under Non-Free-Space Conditions. i 2013 International Conference on Electromagnetics in Advanced Applications (ICEAA). IEEE, s. 1210-1212, Torino, Italien, 09/09/2013. https://doi.org/10.1109/ICEAA.2013.6632438

Estimation of Radiation Limit from a Huygens' Box under Non-Free-Space Conditions. / Franek, Ondrej; Sørensen, Morten; Bonev, Ivan Bonev; Ebert, Hans; Pedersen, Gert Frølund.

2013 International Conference on Electromagnetics in Advanced Applications (ICEAA). IEEE, 2013. s. 1210-1212.

Publikation: Bidrag til bog/antologi/rapport/konference proceedingKonferenceartikel i proceedingForskningpeer review

TY - GEN

T1 - Estimation of Radiation Limit from a Huygens' Box under Non-Free-Space Conditions

AU - Franek, Ondrej

AU - Sørensen, Morten

AU - Bonev, Ivan Bonev

AU - Ebert, Hans

AU - Pedersen, Gert Frølund

PY - 2013

Y1 - 2013

N2 - The recently studied Huygens' box method has difficulties when radiation of an electronic module is to be determined under non-free-space conditions, i.e. with an enclosure. We propose an estimate on radiation limit under such conditions based only on the Huygens' box data from free-space measurements. Numerical experiment shows that the limit is valid everywhere except the resonance frequencies. Consequently, it is argued that knowledge of the inner structure of the module is in fact necessary also for the limit estimation.

AB - The recently studied Huygens' box method has difficulties when radiation of an electronic module is to be determined under non-free-space conditions, i.e. with an enclosure. We propose an estimate on radiation limit under such conditions based only on the Huygens' box data from free-space measurements. Numerical experiment shows that the limit is valid everywhere except the resonance frequencies. Consequently, it is argued that knowledge of the inner structure of the module is in fact necessary also for the limit estimation.

U2 - 10.1109/ICEAA.2013.6632438

DO - 10.1109/ICEAA.2013.6632438

M3 - Article in proceeding

SN - 978-1-4673-5705-0

SP - 1210

EP - 1212

BT - 2013 International Conference on Electromagnetics in Advanced Applications (ICEAA)

PB - IEEE

ER -

Franek O, Sørensen M, Bonev IB, Ebert H, Pedersen GF. Estimation of Radiation Limit from a Huygens' Box under Non-Free-Space Conditions. I 2013 International Conference on Electromagnetics in Advanced Applications (ICEAA). IEEE. 2013. s. 1210-1212 https://doi.org/10.1109/ICEAA.2013.6632438