Façade system for existing office buildings in Copenhagen

Loay Akram Hannoudi, Jørgen Erik Christensen, Michael Lauring

Publikation: Bidrag til tidsskriftKonferenceartikel i tidsskriftForskningpeer review

10 Citationer (Scopus)
250 Downloads (Pure)

Abstract

This study investigates solutions for facade renovation of general office buildings built between 1960 and 1980 in the Copenhagen Municipality. 44 buildings are used for the study. They share common structural and construction principles like the use of beams and columns and prefabricated elements. The problems that face these buildings are a high number of overheating hours and high heating consumption. Four strategies are tested for the renovation: external re-insulation, double-skin facade (existing inner facade), double-skin facade (new inner facade) and curtain wall. External re-insulation and curtain wall provide the best results for reducing the energy consumption for heating.
OriginalsprogEngelsk
TidsskriftEnergy Procedia
Vol/bind78
Sider (fra-til)937-942
ISSN1876-6102
DOI
StatusUdgivet - 2015
Begivenhed6th International Building Physics Conference (IBPC 2015) - Torino, Italien
Varighed: 14 jun. 201517 jun. 2015
Konferencens nummer: 6
http://www.ibpc2015.org/

Konference

Konference6th International Building Physics Conference (IBPC 2015)
Nummer6
Land/OmrådeItalien
ByTorino
Periode14/06/201517/06/2015
Internetadresse

Fingeraftryk

Dyk ned i forskningsemnerne om 'Façade system for existing office buildings in Copenhagen'. Sammen danner de et unikt fingeraftryk.

Citationsformater