Façade system for existing office buildings in Copenhagen

Loay Akram Hannoudi, Jørgen Erik Christensen, Michael Lauring

Publikation: Bidrag til tidsskriftKonferenceartikel i tidsskriftForskningpeer review

3 Citationer (Scopus)
144 Downloads (Pure)

Resumé

This study investigates solutions for facade renovation of general office buildings built between 1960 and 1980 in the Copenhagen Municipality. 44 buildings are used for the study. They share common structural and construction principles like the use of beams and columns and prefabricated elements. The problems that face these buildings are a high number of overheating hours and high heating consumption. Four strategies are tested for the renovation: external re-insulation, double-skin facade (existing inner facade), double-skin facade (new inner facade) and curtain wall. External re-insulation and curtain wall provide the best results for reducing the energy consumption for heating.
OriginalsprogEngelsk
TidsskriftEnergy Procedia
Vol/bind78
Sider (fra-til)937-942
ISSN1876-6102
DOI
StatusUdgivet - 2015
Begivenhed6th International Building Physics Conference (IBPC 2015) - Torino, Italien
Varighed: 14 jun. 201517 jun. 2015
Konferencens nummer: 6
http://www.ibpc2015.org/

Konference

Konference6th International Building Physics Conference (IBPC 2015)
Nummer6
LandItalien
ByTorino
Periode14/06/201517/06/2015
Internetadresse

Fingerprint

Facades
Office buildings
Insulation
Skin
Heating
Energy utilization

Citer dette

@inproceedings{865e5882d0f844aa97ecd9531b06f855,
title = "Fa{\cc}ade system for existing office buildings in Copenhagen",
abstract = "This study investigates solutions for facade renovation of general office buildings built between 1960 and 1980 in the Copenhagen Municipality. 44 buildings are used for the study. They share common structural and construction principles like the use of beams and columns and prefabricated elements. The problems that face these buildings are a high number of overheating hours and high heating consumption. Four strategies are tested for the renovation: external re-insulation, double-skin facade (existing inner facade), double-skin facade (new inner facade) and curtain wall. External re-insulation and curtain wall provide the best results for reducing the energy consumption for heating.",
keywords = "Facade renovation; Sustainable solutions; Energy efficiency; Indoor climate.",
author = "Hannoudi, {Loay Akram} and Christensen, {J{\o}rgen Erik} and Michael Lauring",
year = "2015",
doi = "10.1016/j.egypro.2015.11.023",
language = "English",
volume = "78",
pages = "937--942",
journal = "Energy Procedia",
issn = "1876-6102",
publisher = "Elsevier",

}

Façade system for existing office buildings in Copenhagen. / Hannoudi, Loay Akram; Christensen, Jørgen Erik ; Lauring, Michael.

I: Energy Procedia, Bind 78, 2015, s. 937-942.

Publikation: Bidrag til tidsskriftKonferenceartikel i tidsskriftForskningpeer review

TY - GEN

T1 - Façade system for existing office buildings in Copenhagen

AU - Hannoudi, Loay Akram

AU - Christensen, Jørgen Erik

AU - Lauring, Michael

PY - 2015

Y1 - 2015

N2 - This study investigates solutions for facade renovation of general office buildings built between 1960 and 1980 in the Copenhagen Municipality. 44 buildings are used for the study. They share common structural and construction principles like the use of beams and columns and prefabricated elements. The problems that face these buildings are a high number of overheating hours and high heating consumption. Four strategies are tested for the renovation: external re-insulation, double-skin facade (existing inner facade), double-skin facade (new inner facade) and curtain wall. External re-insulation and curtain wall provide the best results for reducing the energy consumption for heating.

AB - This study investigates solutions for facade renovation of general office buildings built between 1960 and 1980 in the Copenhagen Municipality. 44 buildings are used for the study. They share common structural and construction principles like the use of beams and columns and prefabricated elements. The problems that face these buildings are a high number of overheating hours and high heating consumption. Four strategies are tested for the renovation: external re-insulation, double-skin facade (existing inner facade), double-skin facade (new inner facade) and curtain wall. External re-insulation and curtain wall provide the best results for reducing the energy consumption for heating.

KW - Facade renovation; Sustainable solutions; Energy efficiency; Indoor climate.

U2 - 10.1016/j.egypro.2015.11.023

DO - 10.1016/j.egypro.2015.11.023

M3 - Conference article in Journal

VL - 78

SP - 937

EP - 942

JO - Energy Procedia

JF - Energy Procedia

SN - 1876-6102

ER -