Abstract
Validating safety-critical real-time systems such as in-car networks often involves a model-based performance analysis of the network. An important issue performing such analysis is to provide precise model parameters, matching the actual equipment. One way to obtain such parameters is to derive them by measurements of the equipment. In this work we describe the design of a testbed enabling active measurements on up to 1 [Gb=Sec] Copper based Ethernet Switches. By use of the testbed it self, we conduct a series of tests where the precision of the testbed is estimated. We find a maximum error of 55 [ns] measuring frame traversal time, and quantify the constant error imposed by the testbed it self.
Originalsprog | Engelsk |
---|---|
Titel | ITS Telecommunications (ITST), 2012 12th International Conference on |
Antal sider | 5 |
Forlag | IEEE Press |
Publikationsdato | 2012 |
Sider | 548 - 552 |
ISBN (Trykt) | 978-1-4673-3071-8 |
ISBN (Elektronisk) | 978-1-4673-3069-5 |
DOI | |
Status | Udgivet - 2012 |
Begivenhed | 12th International Conference on ITS Telecommunications - Taipei, Taiwan Varighed: 5 nov. 2012 → 8 nov. 2012 |
Konference
Konference | 12th International Conference on ITS Telecommunications |
---|---|
Land/Område | Taiwan |
By | Taipei |
Periode | 05/11/2012 → 08/11/2012 |