Hygrothermal conditions in ventilated attics with different air change rates and ceiling constructions

Martin Morelli, Eva B. Møller, Thor Hansen

Publikation: Bidrag til bog/antologi/rapport/konference proceedingKonferenceartikel i proceedingForskningpeer review

8 Downloads (Pure)

Abstrakt

A recently Danish study reported that no vapour barrier is needed in ceilings, if the attic is well ventilated and the ceiling towards the dwelling is airtight. Based on that study, new investigations were initiated with focus on the hygrothermal behaviour in ventilated attics with different air change rates. A test house with three sets of four different ceiling constructions – all airtight – was used in this study. The ventilation rate was reduced in two of the sets with approx. 35% and 50%, respectively. Air change rates were measured with tracer gas. Furthermore, temperature and relative humidity was measured every hour. Measurements in similar ceilings with mineral wool or cellulose insulation material show that hygroscopic properties of the insulation have very limited effect on relative humidity. Furthermore, only at low ventilation rate the effect of a vapour barrier could be measured with minor impact. Based on the short measured period the calculations of the risk of mould growth showed no risk. The results indicates that even when the ventilation is reduced by 50 %, the ventilated attic still performs well if the ceiling is highly airtight. However, the importance of vapour barriers becomes more important at lower air change rates.
OriginalsprogEngelsk
Titel12th Nordic Symposium on Building Physics (NSB 2020)
RedaktørerJ. Kurnitski , T. Kalamees
Antal sider7
ForlagEDP Sciences
Publikationsdato30 jun. 2020
Sider1-7
Artikelnummer07008
DOI
StatusUdgivet - 30 jun. 2020
Begivenhed12th Nordic Symposium on Building Physics, NSB 2020 - Tallinn, Estland
Varighed: 6 sep. 20209 sep. 2020

Konference

Konference12th Nordic Symposium on Building Physics, NSB 2020
Land/OmrådeEstland
ByTallinn
Periode06/09/202009/09/2020
NavnE3S Web of Conferences
Vol/bind172
ISSN2267-1242

Fingeraftryk

Dyk ned i forskningsemnerne om 'Hygrothermal conditions in ventilated attics with different air change rates and ceiling constructions'. Sammen danner de et unikt fingeraftryk.
  • Air change rate in ventilated attics – reality and input for simulations

    Møller, E. B., Morelli, M. & Hansen, T., sep. 2019, MATEC Web of Conferences: 4th Central European Symposium on Building Physics (CESBP 2019). Černý, R., Kočí, J. & Kočí, V. (red.). Prague, Czech Republic: EDP Sciences, s. 1-6 6 s. 02073. (MATEC Web of Conferences, Bind 282).

    Publikation: Bidrag til bog/antologi/rapport/konference proceedingKonferenceartikel i proceedingForskningpeer review

    Åben adgang
    Fil
    111 Downloads (Pure)

Citationsformater