N1 - © 2018 Wiley Periodicals, Inc.
PY - 2019/3/1
Y1 - 2019/3/1
N2 - OBJECTIVES: In this substudy of the SORT OUT VII trial, the clinical outcomes among patient with diabetes mellitus treated with Orsiro sirolimus-eluting stent (O-SES; Biotronik, Bülach, Switzerland) or Nobori biolimus-eluting stent (N-BES; Terumo, Tokyo, Japan) were compared.BACKGROUND: Diabetes is associated with increased risk of target lesion failure (TLF) after percutaneous coronary intervention.METHODS: In total, 2525 patients were randomized to stent implantation with O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). The primary endpoint, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 2 years.RESULTS: At 2 year, TLF did not differ between O-SES vs N-BES in diabetic (9.3% vs 9.4%; RR 0.98, 95% CI 0.54-1.78) patients. The individual components of the primary endpoint did not differ among stent type. In diabetics, cardiac death occurred in 3% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.77, 95% CI 0.29-2.08), MI occurred in 3.0% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.76, 95% CI 0.28-2.06) and TLR occurred in 5,5% of O-SES-treated and in 6.0% of N-BES-treated patients (RR 0.91, 95% CI 0.43-1.95).CONCLUSION: TLF did not differ between O-SES- and N-BES-treated diabetic patients.
AB - OBJECTIVES: In this substudy of the SORT OUT VII trial, the clinical outcomes among patient with diabetes mellitus treated with Orsiro sirolimus-eluting stent (O-SES; Biotronik, Bülach, Switzerland) or Nobori biolimus-eluting stent (N-BES; Terumo, Tokyo, Japan) were compared.BACKGROUND: Diabetes is associated with increased risk of target lesion failure (TLF) after percutaneous coronary intervention.METHODS: In total, 2525 patients were randomized to stent implantation with O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). The primary endpoint, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 2 years.RESULTS: At 2 year, TLF did not differ between O-SES vs N-BES in diabetic (9.3% vs 9.4%; RR 0.98, 95% CI 0.54-1.78) patients. The individual components of the primary endpoint did not differ among stent type. In diabetics, cardiac death occurred in 3% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.77, 95% CI 0.29-2.08), MI occurred in 3.0% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.76, 95% CI 0.28-2.06) and TLR occurred in 5,5% of O-SES-treated and in 6.0% of N-BES-treated patients (RR 0.91, 95% CI 0.43-1.95).CONCLUSION: TLF did not differ between O-SES- and N-BES-treated diabetic patients.
KW - Nobori stent
KW - Orsiro stent
KW - drug-eluting stent
KW - target lesion failure
UR - http://www.scopus.com/inward/record.url?scp=85053716988&partnerID=8YFLogxK
U2 - 10.1002/ccd.27891
DO - 10.1002/ccd.27891
M3 - Journal article
C2 - 30244533
SN - 1522-1946
VL - 93
SP - 567
EP - 573
JO - Catheterization and Cardiovascular Interventions
JF - Catheterization and Cardiovascular Interventions
IS - 4
ER -