Abstract
This paper proposes an optimization scheme for traditional refrigeration systems with hysteresis controllers and scheduled defrosts. It aims at minimizing the side effect of defrost cycles on the storage quality of refrigerated foodstuffs in supermarkets. By utilizing the thermal mass of air and products inside a display cabinet, this optimization scheme forces the compressor to work harder and cool down more prior to the scheduled defrosts, thus guaranteeing the product temperature after defrost cycles still to be within a controlled safe level.
Originalsprog | Engelsk |
---|---|
Tidsskrift | American Control Conference (ACC) |
Sider (fra-til) | 1836-1841 |
Antal sider | 5 |
ISSN | 0743-1619 |
Status | Udgivet - 2008 |
Begivenhed | American Control Conference, 2008 - Seattle, Washington, USA Varighed: 11 jun. 2008 → 13 jun. 2008 |
Konference
Konference | American Control Conference, 2008 |
---|---|
Land/Område | USA |
By | Seattle, Washington |
Periode | 11/06/2008 → 13/06/2008 |