T1 - Model Predictive Control of LC-Filtered Voltage Source Inverters With Optimal Switching Sequence
AU - Zheng, Changming
AU - Dragicevic, Tomislav
AU - Zhang, Zhenbing
AU - Rodriguez, Jose
AU - Blaabjerg, Frede
PY - 2021/3
Y1 - 2021/3
N2 - Voltage source inverters with output LC filter enable a sinusoidal output voltage with low harmonics, suitable for islanded ac microgrid or uninterruptible power supply applications. Conventional finite-set model predictive voltage control (MPVC) applies only a single switching vector per control period, leading to a variable switching frequency and significant output ripple. This article resolves these issues by proposing an improved MPVC with optimal switching sequence (OSS-MPVC). First, an improved vector switching sequence is defined, aiming to reduce the output-voltage ripple with a constant switching frequency. Then, to tackle the difficulty in extending the OSS to high-order systems due to the coupling effect of the output filter, a generalized 'one-step estimation' solution is proposed, which directly associates the control-variable gradients with the vector switching sequence. To further enhance the output-voltage tracking accuracy, intersample dynamics are taken into account in the cost function. The control delay and dead-time compensation are also considered. Simulations and experimental results verify the feasibility of the proposed method.
AB - Voltage source inverters with output LC filter enable a sinusoidal output voltage with low harmonics, suitable for islanded ac microgrid or uninterruptible power supply applications. Conventional finite-set model predictive voltage control (MPVC) applies only a single switching vector per control period, leading to a variable switching frequency and significant output ripple. This article resolves these issues by proposing an improved MPVC with optimal switching sequence (OSS-MPVC). First, an improved vector switching sequence is defined, aiming to reduce the output-voltage ripple with a constant switching frequency. Then, to tackle the difficulty in extending the OSS to high-order systems due to the coupling effect of the output filter, a generalized 'one-step estimation' solution is proposed, which directly associates the control-variable gradients with the vector switching sequence. To further enhance the output-voltage tracking accuracy, intersample dynamics are taken into account in the cost function. The control delay and dead-time compensation are also considered. Simulations and experimental results verify the feasibility of the proposed method.
KW - Fixed switching frequency
KW - inverters
KW - microgrid
KW - model predictive control (MPC)
KW - optimal switching sequence (OSS)
UR - http://www.scopus.com/inward/record.url?scp=85095684390&partnerID=8YFLogxK
U2 - 10.1109/TPEL.2020.3015540
DO - 10.1109/TPEL.2020.3015540
M3 - Journal article
SN - 0885-8993
VL - 36
SP - 3422
EP - 3436
JO - I E E E Transactions on Power Electronics
JF - I E E E Transactions on Power Electronics
IS - 3
M1 - 9165198