Nonlinear Coss-VDS Profile based ZVS Range Calculation for Dual Active Bridge Converters

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

18 Citationer (Scopus)
321 Downloads (Pure)

Abstract

Generally, power electronic converters are designed to obtain the highest efficiency at rated power while they are most often operated under partial loading conditions. For dual active bridge converters, the zero-voltage-switching (ZVS) conditions can be impaired under light load situations. While load depending ZVS operation has been introduced by prior-art approaches, the nonlinear characteristic of the output capacitance in a power device is often not considered and its effect on operating boundaries of ZVS is neglected. In this letter, based on practical switching transients, an improved method of calculating the ZVS range is introduced. By taking into account the nonlinearity of output capacitance, the method is developed from a detailed analysis of real switching transients. A 2.5-kW prototype is built, and a comprehensive comparison with prior-art approaches is conducted to validate the accuracy of the proposed method.

OriginalsprogEngelsk
Artikelnummer9119872
TidsskriftI E E E Transactions on Power Electronics
Vol/bind36
Udgave nummer1
Sider (fra-til)45-50
Antal sider6
ISSN0885-8993
DOI
StatusUdgivet - jan. 2021

Fingeraftryk

Dyk ned i forskningsemnerne om 'Nonlinear Coss-VDS Profile based ZVS Range Calculation for Dual Active Bridge Converters'. Sammen danner de et unikt fingeraftryk.

Citationsformater