Radon in Rented Accommodation and Variables Determining Its Level

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

289 Downloads (Pure)

Abstract

Indoor radon levels were measured in 221 homes in rented accommodation. In addition, buildings were registered for a
series of variables describing building characteristics and used materials. The mean year value of the indoor radon level was 30.7 (1~250) Bq/m3. The indoor radon level exceeded 100 Bq/m3 in 5.9% of the homes. Of the investigated variables, only homes in single-family terraced houses, were statistically significant. Approx. 75% of homes exceeding 100 Bq/m3 indoor radon level had levels between 100 and 200 Bq/m3 and 25% had indoor radon levels exceeding 200 Bq/m3. Significant differences in indoor radon levels were found in homes located in multi-occupant houses. Additionally, the risk of indoor radon levels exceeding 100 Bq/m3 in homes in multi-occupant houses was found to be very low, but the risk was the highest on the ground floor in a building constructed with slab on ground.
OriginalsprogEngelsk
TidsskriftJournal of Civil Engineering and Architecture
Vol/bind11
Udgave nummer6
Sider (fra-til)538-549
Antal sider12
ISSN1934-7359
DOI
StatusUdgivet - 25 jun. 2017

Emneord

  • Radon
  • indoor
  • distribution
  • building characteristics