TY - JOUR
T1 - Rapid antimicrobial susceptibility testing of clinical isolates by digital time-lapse microscopy
AU - Fredborg, Marlene
AU - Rosenvinge, Flemming L
AU - Spillum, Erik
AU - Krogsbo, Stine
AU - Wang, Mikala
AU - Søndergaard, Teis Esben
PY - 2015/9/25
Y1 - 2015/9/25
N2 - Rapid antimicrobial susceptibility testing (AST) is essential for early and appropriate therapy. Methods with short detection time enabling same-day treatment optimisation are highly favourable. In this study, we evaluated the potential of a digital time-lapse microscope system, the oCelloScope system, to perform rapid AST. The oCelloScope system demonstrated a very high accuracy (96 % overall agreement) when determining the resistance profiles of four reference strains, nine clinical isolates, including multi-drug-resistant isolates, and three positive blood cultures. AST of clinical isolates (168 antimicrobial agent-organism combinations) demonstrated 3.6 % minor, no major and 1.2 % very major errors of the oCelloScope system compared to conventional susceptibility testing, as well as a rapid and correct phenotypic detection of strains with methicillin-resistant Staphylococcus aureus (MRSA) and extended-spectrum β-lactamase (ESBL) profiles. The net average time-to-result was 108 min, with 95 % of the results being available within 180 min. In conclusion, this study strongly indicates that the oCelloScope system holds considerable potential as an accurate and sensitive AST method with short time-to-result, enabling same-day targeted antimicrobial therapy, facilitating antibiotic stewardship and better patient management. A full-scale validation of the oCelloScope system including more isolates is necessary to assess the impact of using it for AST.
AB - Rapid antimicrobial susceptibility testing (AST) is essential for early and appropriate therapy. Methods with short detection time enabling same-day treatment optimisation are highly favourable. In this study, we evaluated the potential of a digital time-lapse microscope system, the oCelloScope system, to perform rapid AST. The oCelloScope system demonstrated a very high accuracy (96 % overall agreement) when determining the resistance profiles of four reference strains, nine clinical isolates, including multi-drug-resistant isolates, and three positive blood cultures. AST of clinical isolates (168 antimicrobial agent-organism combinations) demonstrated 3.6 % minor, no major and 1.2 % very major errors of the oCelloScope system compared to conventional susceptibility testing, as well as a rapid and correct phenotypic detection of strains with methicillin-resistant Staphylococcus aureus (MRSA) and extended-spectrum β-lactamase (ESBL) profiles. The net average time-to-result was 108 min, with 95 % of the results being available within 180 min. In conclusion, this study strongly indicates that the oCelloScope system holds considerable potential as an accurate and sensitive AST method with short time-to-result, enabling same-day targeted antimicrobial therapy, facilitating antibiotic stewardship and better patient management. A full-scale validation of the oCelloScope system including more isolates is necessary to assess the impact of using it for AST.
UR - http://link.springer.com/article/10.1007%2Fs10096-015-2492-9
U2 - 10.1007/s10096-015-2492-9
DO - 10.1007/s10096-015-2492-9
M3 - Journal article
SN - 0934-9723
VL - 34
SP - 2385
EP - 2394
JO - European Journal of Clinical Microbiology & Infectious Diseases
JF - European Journal of Clinical Microbiology & Infectious Diseases
IS - 12
ER -