Study on pollution control in residential kitchen based on the push-pull ventilation system

Bin Zhou, Feng Chen, Zhibo Dong, Peter Vilhelm Nielsen

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

68 Citationer (Scopus)

Abstract

Highlights
•The push-pull ventilation system is proposed to improve IAQ inside kitchen, where air is supplied through slot air curtain and then exhausted through range hood.
•CO2 reduction efficiency with application of air curtain in experiment and simulation in breathing zone was 23.7% and 23.1%, respectively.
•By orthogonal method, the influence of factors on pollution control of the push-pull ventilation system was presented.