Projekter pr. år
Abstract
A study was carried out to investigate whether an elevated room temperature in a summer heat wave affects a subject’s mental status, self-assessed performance or impairs a subject’s mental performance. In a simulated office environment 20 subjects were exposed to different air temperature conditions: 23-26°C, repeated once, 29-32°C and 33-35°C during outside summer conditions. In the course of 4.25 h selective attention, verbal and numerical thinking did not change significantly neither with temperature nor time. Slight effects on performance were found for text correction. The willingness to exert effort and the feeling of being relaxed decreased significantly both with temperature and time. Drowsiness tended to increase with temperature and rose significantly with time. The feeling of being well-adjusted and self-assessed performance tended to decrease with increasing temperature. The mental and physical work load were perceived to be higher when the temperatures where higher. The results imply the subject’s ability to adjust their mental performance in relation to heat strain. A longer exposure time may lead to different results.
Originalsprog | Engelsk |
---|---|
Titel | Healthy Buildings 2012. 10th International Conference : 8 -12 July 2012, Brisbane, Australia Brisbane: Queensland University of Technology, 2012 |
Antal sider | 6 |
Udgivelsessted | Brisbane |
Forlag | International Society of Indoor Air Quality and Climate |
Publikationsdato | 2012 |
Artikelnummer | 3D-9/ 7C-7 |
ISBN (Elektronisk) | 978-1-921897-40-5 |
Status | Udgivet - 2012 |
Udgivet eksternt | Ja |
Fingeraftryk
Dyk ned i forskningsemnerne om 'Subjective and Objective Assessment of Office Performance and Heat Strain at Elevated Temperatures - The HESO-Study.'. Sammen danner de et unikt fingeraftryk.Projekter
- 2 Afsluttet
-
05 - Office Buildings: Overview on projects at my previous affiliations
Hellwig, R. T. (Andet)
01/08/1995 → 30/09/2018
Projekter: Projekt › Forskning
Fil -
01 - Human well-being and technology in architecture: Overview on projects at my previous affiliations and actual projects
Hellwig, R. T. (Andet)
01/08/1995 → 30/09/2018
Projekter: Projekt › Forskning
Fil
Impacts
-
HESO Project: Impact 2017: 4114 downloads of "Heat strain and performance in offices at elevated outside temperatures. Final Report F2039"
Hellwig, R. T. (Deltager)
Impact: Livskvalitets impact, Politisk impact
-
HESO Project: Impact 2019: 4090 downloads of "Heat strain and performance in offices at elevated outside temperatures. Final Report F2039"
Hellwig, R. T. (Deltager)
Impact: Politisk impact, Livskvalitets impact