T1 - Superior fixation and less periprosthetic stress-shielding of tibial components with a finned stem versus an I-beam block stem
T2 - a randomized RSA and DXA study with minimum 5 years' follow-up
AU - Stilling, Maiken
AU - Mechlenburg, Inger
AU - Jepsen, Claus Fink
AU - Rømer, Lone
AU - Rahbek, Ole
AU - Søballe, Kjeld
AU - Madsen, Frank
PY - 2019/1/23
Y1 - 2019/1/23
N2 - Background and purpose - The stem on the tibial component of total knee arthroplasty provides mechanical resistance to lift-off, shear forces, and torque. We compared tibial components with finned stems (FS) and I-beam block stems (IS) to assess differences in implant migration. Patients and methods - In a patient-blinded RCT, 54 patients/knees (15 men) with knee osteoarthritis at a mean age of 77 years (70-90) were randomly allocated to receive tibial components with either a FS (n = 27) or an IS (n = 27). Through 5 to 7 years' follow-up, implant migration was measured with RSA, periprosthetic bone mineral density (BMD) was measured with DXA, and surgeons reported American Knee Society Score (AKSS). Results - At minimum 5 years' follow-up, maximum total point motion (MTPM) was higher (p = 0.04) for IS (1.48 mm, 95% CI 0.81-2.16) than for FS (0.85 mm, CI 0.38-1.32) tibial components. Likewise, total rotation (TR) was higher (p = 0.03) for IS (1.51˚, CI 0.78-2.24) than for FS (0.81˚, CI 0.36-1.27). Tibial components with IS externally rotated 0.50° (CI -0.06 to 1.06) while FS internally rotated 0.09° (CI -0.20 to 0.38) (p = 0.03). Periprosthetic bone stress-shielding was higher (p <0.01) up to 2 years' follow-up for IS compared with FS in the regions medial to the stem (-13% vs. -2%) and posterior to the stem (-13% vs. -2%). Below the stem bone loss was also higher (p = 0.01) for IS compared with FS (-6% vs. +1%) up to 1-year follow-up. Knee score improved similarly in both groups up to 5 years' follow-up. Interpretation - Periprosthetic bone stress-shielding medial and posterior to the stem until 2 years, and tibial component migration at 5 years, was less for a finned compared with an I-shaped block stem design.
AB - Background and purpose - The stem on the tibial component of total knee arthroplasty provides mechanical resistance to lift-off, shear forces, and torque. We compared tibial components with finned stems (FS) and I-beam block stems (IS) to assess differences in implant migration. Patients and methods - In a patient-blinded RCT, 54 patients/knees (15 men) with knee osteoarthritis at a mean age of 77 years (70-90) were randomly allocated to receive tibial components with either a FS (n = 27) or an IS (n = 27). Through 5 to 7 years' follow-up, implant migration was measured with RSA, periprosthetic bone mineral density (BMD) was measured with DXA, and surgeons reported American Knee Society Score (AKSS). Results - At minimum 5 years' follow-up, maximum total point motion (MTPM) was higher (p = 0.04) for IS (1.48 mm, 95% CI 0.81-2.16) than for FS (0.85 mm, CI 0.38-1.32) tibial components. Likewise, total rotation (TR) was higher (p = 0.03) for IS (1.51˚, CI 0.78-2.24) than for FS (0.81˚, CI 0.36-1.27). Tibial components with IS externally rotated 0.50° (CI -0.06 to 1.06) while FS internally rotated 0.09° (CI -0.20 to 0.38) (p = 0.03). Periprosthetic bone stress-shielding was higher (p <0.01) up to 2 years' follow-up for IS compared with FS in the regions medial to the stem (-13% vs. -2%) and posterior to the stem (-13% vs. -2%). Below the stem bone loss was also higher (p = 0.01) for IS compared with FS (-6% vs. +1%) up to 1-year follow-up. Knee score improved similarly in both groups up to 5 years' follow-up. Interpretation - Periprosthetic bone stress-shielding medial and posterior to the stem until 2 years, and tibial component migration at 5 years, was less for a finned compared with an I-shaped block stem design.
KW - Absorptiometry, Photon/methods
KW - Aged
KW - Arthroplasty, Replacement, Knee/adverse effects
KW - Bone Density
KW - Female
KW - Humans
KW - Knee Joint/pathology
KW - Knee Prosthesis/adverse effects
KW - Male
KW - Osteoarthritis, Knee/surgery
KW - Prosthesis Design
KW - Prosthesis Failure/etiology
KW - Tibia/pathology
KW - Treatment Outcome
UR - http://www.scopus.com/inward/record.url?scp=85060566832&partnerID=8YFLogxK
U2 - 10.1080/17453674.2019.1566510
DO - 10.1080/17453674.2019.1566510
M3 - Journal article
C2 - 30669918
SN - 1745-3674
VL - 90
SP - 165
EP - 171
JO - Acta Orthopaedica (Print Edition)
JF - Acta Orthopaedica (Print Edition)
IS - 2
ER -