Technical solutions for reducing indoor residential exposures to ultrafine particles from second-hand cigarette smoke infiltration

Alireza Afshari, Siamak Rahimi Ardkapan, Niels Christian Bergsøe, Matthew S. Johnson

Publikation: Bidrag til bog/antologi/rapport/konference proceedingKonferenceartikel i proceedingForskningpeer review

Abstract

An emerging public issue in Denmark is passive smoking in residential environments where non-smokers are exposed to harmful smoke from their neighbours. There are various ways that smoke infiltrates one flat from another. The air infiltration rate between two flats in a multi-storey building depends on the construction, tightness and age of the building. Earlier results from this project showed that, in the most critical cases, the transfer of ultrafine particles was about 9% when the source flat was located below the receiving flat. The purpose of the present study was to identify the ways in which smoke infiltrates from one flat to another and also to examine technical solutions for preventing or reducing infiltration of ultrafine particles from the source flat to the receiving flat. One of the technical solutions examined was sealing of the floor in the receiving flat. The study was carried out in the field in a multi-storey building and cardboard and plastic foil of polyethylene were used for sealing the entire wooden floor in the receiving flat. Another technical solution examined was a novel air circulating ductwork. The efficiency of the novel air circulating ductwork was examined by investigating the removal of ultrafine particles from a lit cigarette in a laboratory environment. The results showed that in the case where the receiving flat was sealed, the concentration of particles in the receiving flat was non-correlated with (or independent of) the emission of particles in the source flat. The test of the air circulating ductwork showed that the removal efficiency ranged from approx. 30% to 60% after 10 minutes, i.e. when the cigarette had burned out.
OriginalsprogEngelsk
TitelIndoor Air
ForlagInternational Society of Indoor Air Quality and Climate
Publikationsdato2011
StatusUdgivet - 2011
BegivenhedThe 12th International Conference on Indoor Air Quality and Climate (Indoor Air 2011) - Austin, Texas, USA
Varighed: 5 jun. 201110 jun. 2011
Konferencens nummer: 12

Konference

KonferenceThe 12th International Conference on Indoor Air Quality and Climate (Indoor Air 2011)
Nummer12
Land/OmrådeUSA
ByAustin, Texas
Periode05/06/201110/06/2011
NavnProceedings from Indoor Air 2011

Bibliografisk note

Proceedings on USB stick.

Fingeraftryk

Dyk ned i forskningsemnerne om 'Technical solutions for reducing indoor residential exposures to ultrafine particles from second-hand cigarette smoke infiltration'. Sammen danner de et unikt fingeraftryk.

Citationsformater