The Bearing Capacity of Circular Footings in Sand: Comparison between Model Tests and Numerical Simulations Based on a Nonlinear Mohr Failure Envelope

Sven Krabbenhøft, Johan Clausen, Lars Damkilde

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

13 Citationer (Scopus)

Abstract

This paper presents the results of a series of triaxial tests with dry sand at confining pressures varying from 1.5 kPa to 100 kPa at relative densities of 0.20, 0.59 and 0.84. The results, which are in reasonable accordance with an equation given by Bolton, show that the friction angle is strongly dependent on the stress level and on the basis of the test results, a non linear Mohr failure criterion has been proposed. This yield criterion has been implemented in a finite element program and an analysis of the bearing capacity of a circular shaped model foundation, diameter 100mm, has been conducted.
Comparisons have been made with results from 1g model scale tests with a foundation of similar size and a good agreement between numerical results and test results has been found.
OriginalsprogEngelsk
TidsskriftAdvances in Civil Engineering
Vol/bind2012
Antal sider10
ISSN1687-8086
DOI
StatusUdgivet - 2012

Bibliografisk note

Article ID 947276

Emneord

  • Triaxial Tests
  • Low Confining Pressure
  • Shallow Foundations
  • Non Linear
  • Dilation
  • Friction Angle
  • Finite Element Simulation
  • 1g Model Tests

Fingeraftryk

Dyk ned i forskningsemnerne om 'The Bearing Capacity of Circular Footings in Sand: Comparison between Model Tests and Numerical Simulations Based on a Nonlinear Mohr Failure Envelope'. Sammen danner de et unikt fingeraftryk.