The impact of stapling technique and surgeon specialism on anastomotic failure after right-sided colorectal resection: an international multicentre, prospective audit

Inge Bernstein (Medlem af forfattergruppering), Kåre Gotschalck Sunesen (Medlem af forfattergruppering), Jonathan Leunbach (Medlem af forfattergruppering), Ole Thorlacius-Ussing (Medlem af forfattergruppering), Anders Uth Ovesen (Medlem af forfattergruppering), 2015 European Society of Coloproctology collaborating group

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

31 Citationer (Scopus)
96 Downloads (Pure)

Abstract

AIM: There is little evidence to support choice of technique and configuration for stapled anastomoses after right hemicolectomy and ileocaecal resection. This study aimed to determine the relationship between stapling technique and anastomotic failure.

METHOD: Any unit performing gastrointestinal surgery was invited to contribute data on consecutive adult patients undergoing right hemicolectomy or ileocolic resection to this prospective, observational, international, multicentre study. Patients undergoing stapled, side-to-side ileocolic anastomoses were identified and multilevel, multivariable logistic regression analyses were performed to explore factors associated with anastomotic leak.

RESULTS: One thousand three hundred and forty-seven patients were included from 200 centres in 32 countries. The overall anastomotic leak rate was 8.3%. Upon multivariate analysis there was no difference in leak rate with use of a cutting stapler for apical closure compared with a noncutting stapler (8.4% vs 8.0%, OR 0.91, 95% CI 0.54-1.53, P = 0.72). Oversewing of the apical staple line, whether in the cutting group (7.9% vs 9.7%, OR 0.87, 95% CI 0.52-1.46, P = 0.60) or noncutting group (8.9% vs 5.7%, OR 1.40, 95% CI 0.46-4.23, P = 0.55) also conferred no benefit in terms of reducing leak rates. Surgeons reporting to be general surgeons had a significantly higher leak rate than those reporting to be colorectal surgeons (12.1% vs 7.3%, OR 1.65, 95% CI 1.04-2.64, P = 0.04).

CONCLUSION: This study did not identify any difference in anastomotic leak rates according to the type of stapling device used to close the apical aspect. In addition, oversewing of the anastomotic staple lines appears to confer no benefit in terms of reducing leak rates. Although general surgeons operated on patients with more high-risk characteristics than colorectal surgeons, a higher leak rate for general surgeons which remained after risk adjustment needs further exploration.

OriginalsprogEngelsk
TidsskriftColorectal Disease
Vol/bind20
Udgave nummer11
Sider (fra-til)1028-1040
Antal sider13
ISSN1462-8910
DOI
StatusUdgivet - nov. 2018

Bibliografisk note

Colorectal Disease © 2018 The Association of Coloproctology of Great Britain and Ireland.

Fingeraftryk

Dyk ned i forskningsemnerne om 'The impact of stapling technique and surgeon specialism on anastomotic failure after right-sided colorectal resection: an international multicentre, prospective audit'. Sammen danner de et unikt fingeraftryk.

Citationsformater