Uncertainties Related to Extreme Event Statistics of Sewer System Surcharge and Overflow

Kjeld Schaarup-Jensen, C. Johansen, Søren Liedtke Thorndahl

Publikation: Bidrag til bog/antologi/rapport/konference proceedingKonferenceartikel i proceedingForskningpeer review

401 Downloads (Pure)

Abstrakt

Today it is common practice - in the major part of Europe - to base design of sewer systems in urban areas on recommended minimum values of flooding frequencies related to either pipe top level, basement level in buildings or level of road surfaces. Thus storm water runoff in sewer systems is only proceeding in an acceptable manner, if flooding of these levels is having an average return period bigger than a predefined value. This practice is also often used in functional analysis of existing sewer systems. If a sewer system can fulfil recommended flooding frequencies or not, can only be verified by performing long term simulations - using a sewer flow simulation model - and draw up extreme event statistics from the model simulations. In this context it is important to realize that uncertainties related to the input parameters of rainfall runoff models will give rise to uncertainties related to the corresponding extreme event statistics. This paper illustrates this problem in a case study with two different values of one input parameter - the hydrological reduction factor - in two otherwise identical operations of the MOUSE LTS model. The use of a long historical rainfall time series makes it possible to draw up extreme event statistics covering return periods of as much as 33 years. By comparing these two different extreme event statistics it is evident that these to a great extent depend on the uncertainties related to the input parameters of the rainfall runoff model.
OriginalsprogEngelsk
TitelProceedings of the 10th International Conference on Urban Drainage : Copenhagen, Denmark, 21-26 August 2005
RedaktørerEva Eriksson, Hülya Genc-Fuhrman, Thorkild Hvitved-Jacobsen, Anna Ledin, Peter Steen Mikkelsen, Jes Vollertsen
Antal sider8
ForlagInstitute of Environment
Publikationsdato2005
Sider1-8
StatusUdgivet - 2005
BegivenhedInternational Conference on Urban Drainage - Copenhagen, Danmark
Varighed: 21 aug. 200526 aug. 2005
Konferencens nummer: 10

Konference

KonferenceInternational Conference on Urban Drainage
Nummer10
Land/OmrådeDanmark
ByCopenhagen
Periode21/08/200526/08/2005

Bibliografisk note

The proceedings is also published on a CD

Emneord

  • Hydrological Reduction Factor
  • Initial Loss
  • Urban Runoff Modelling
  • MOUSE LTS
  • Extreme Event Statistics
  • Combined Sewer Overflow
  • Flooding

Fingeraftryk

Dyk ned i forskningsemnerne om 'Uncertainties Related to Extreme Event Statistics of Sewer System Surcharge and Overflow'. Sammen danner de et unikt fingeraftryk.

Citationsformater