A new fiducial marker for Image-guided radiotherapy of prostate cancer: clinical experience.

Jesper Carl, Jane Nielsen, Mats Holmberg, Erik Højkjaer Larsen, Knud Fabrin, Rune V Fisker

Research output: Contribution to journalJournal articleResearchpeer-review

14 Citations (Scopus)

Abstract

BACKGROUND: A new fiducial marker for image guided radiotherapy (IGRT) based on a removable prostate stent made of Ni Ti has been developed during two previous clinical feasibility studies. The marker is currently being evaluated for IGRT treatment in a third clinical study. METHOD: The new marker is used to co-register MR and planning CT scans with high accuracy in the region around the prostate. The co-registered MR-CT volumes are used for delineation of GTV before planning. In each treatment session the IGRT system is used to position the patient before treatment. The IGRT system use a stereo pair of kV images matched to corresponding Digital Reconstructed Radiograms (DRR) from the planning CT scan. The match is done using mutual gray scale information. The pair of DRR's for positioning is created in the IGRT system with a threshold in the Look Up Table (LUT). The resulting match provides the necessary shift in couch coordinates to position the stent with an accuracy of 1-2 mm within the planned position. RESULTS: At the present time 39 patients have received the new marker. Of the 39 one has migrated to the bladder. Deviations of more than 5 mm between CTV outlined on CT and MR are seen in several cases and in anterior-posterior (AP), left-right (LR) and cranial-caudal (CC) directions. Intra-fraction translation movements up to +/- 3 mm are seen as well. As the stent is also clearly visible on images taken with high voltage x-rays using electronic portal images devices (EPID), the positioning has been verified independently of the IGRT system. DISCUSSION: The preliminary result of an on going clinical study of a Ni Ti prostate stent, potentially a new fiducial marker for image guided radiotherapy, looks promising. The risk of migration appears to be much lower compared to previous designs.
Original languageEnglish
JournalActa Oncologica
Volume47
Pages (from-to)1358-66
Number of pages8
ISSN0284-186X
DOIs
Publication statusPublished - 2008
Externally publishedYes

Keywords

  • Humans
  • Magnetic Resonance Imaging
  • Male
  • Prostatic Neoplasms
  • Radiotherapy Planning, Computer-Assisted
  • Stents
  • Tomography, X-Ray Computed

Fingerprint

Dive into the research topics of 'A new fiducial marker for Image-guided radiotherapy of prostate cancer: clinical experience.'. Together they form a unique fingerprint.

Cite this