TY - JOUR
T1 - A novel framework for assessing the smartness and the smart readiness level in highly electrified non-residential buildings
T2 - A Norwegian case study
AU - Campodonico Avendano, Italo Aldo
AU - Heimar Andersen, Kamilla
AU - Erba, Silvia
AU - Moazami, Amin
AU - Aghaei, Mohammadreza
AU - Najafi, Behzad
N1 - Publisher Copyright:
© 2024 The Author(s)
PY - 2024/7/1
Y1 - 2024/7/1
N2 - This work presents a new operational framework to measure the smartness and smart readiness of highly electrified buildings. The framework seeks to enhance legacy systems and controls of existing buildings and establish minimum criteria for future constructions to ensure they interact effectively with users and the grid, aiming for a clean energy transition. To this end, we develop two modified complementary assessments, one based on the method indicated by the Smart Readiness Indicator (SRI), proposed by the European Union (EU), and the other following the Smart by Powerhouse scheme, introduced by a Norwegian consortium of stakeholders focused on developing future proof climate buildings. The proposed structure is implemented in ten non-residential buildings in Norway with different energy systems, typologies, and construction dates. The results of this study demonstrate that energy flexibility quantification plays a crucial role in correctly implementing the framework in highly electrified buildings. Therefore, the dynamic impact of having Electric Vehicle Charging (EVC) and other electrical-dependent loads must be considered in the assessment. With the proposed modifications, the EVC weight in the flexibility score now varies from 24.0 to 43.6%, up from the original 5%. Overall, the pilot buildings have a smart readiness level between 21.6% and 31.7%, with mostly automated smartness levels. Nevertheless, the study also emphasizes the need to differentiate current HVAC (Heating, Ventilation, and Air Conditioning) technologies and their efficiencies.
AB - This work presents a new operational framework to measure the smartness and smart readiness of highly electrified buildings. The framework seeks to enhance legacy systems and controls of existing buildings and establish minimum criteria for future constructions to ensure they interact effectively with users and the grid, aiming for a clean energy transition. To this end, we develop two modified complementary assessments, one based on the method indicated by the Smart Readiness Indicator (SRI), proposed by the European Union (EU), and the other following the Smart by Powerhouse scheme, introduced by a Norwegian consortium of stakeholders focused on developing future proof climate buildings. The proposed structure is implemented in ten non-residential buildings in Norway with different energy systems, typologies, and construction dates. The results of this study demonstrate that energy flexibility quantification plays a crucial role in correctly implementing the framework in highly electrified buildings. Therefore, the dynamic impact of having Electric Vehicle Charging (EVC) and other electrical-dependent loads must be considered in the assessment. With the proposed modifications, the EVC weight in the flexibility score now varies from 24.0 to 43.6%, up from the original 5%. Overall, the pilot buildings have a smart readiness level between 21.6% and 31.7%, with mostly automated smartness levels. Nevertheless, the study also emphasizes the need to differentiate current HVAC (Heating, Ventilation, and Air Conditioning) technologies and their efficiencies.
KW - Building stock
KW - Digitalization
KW - Energy use
KW - Non-residential buildings
KW - Norway
KW - Smart buildings
KW - Smart by Powerhouse
KW - SRI
UR - http://www.scopus.com/inward/record.url?scp=85193044978&partnerID=8YFLogxK
U2 - 10.1016/j.enbuild.2024.114234
DO - 10.1016/j.enbuild.2024.114234
M3 - Journal article
AN - SCOPUS:85193044978
SN - 0378-7788
VL - 314
JO - Energy and Buildings
JF - Energy and Buildings
M1 - 114234